INSTALLATION | GUARANTEE | ENVIRONMENT AND RECYCLING
Commissioning
f Route a 4-core bus cable from the ventilation unit to the
mounting position of the programming unit. Use a screened
electronic cable such as LiYCY 2x2x0.8 mm². Do not route the
cable parallel to a three-phase cable.
The BUS cable must protrude 20 to 30 cm out of the wall to allow
installation.
Installation with a flush box
For securing to a wall we recommend using a flush box, which can
hold the part of the bus cable protruding from the wall.
f Make sure that the screws supporting the flush box are ar-
ranged either vertically or horizontally opposite one another.
f Route the bus cable through the aperture in the wall mount-
ed enclosure from the back.
Installation without a flush box
f To secure the wall mounted enclosure, drill four holes
(Ø 5 mm).
f When routing the BUS cable, be careful not to damage the
cable when drilling the fixing holes.
In the area around the power cable entry (behind the wall mount-
ing enclosure), a reservoir needs to be made to hold 20 to 30 cm
of data cable.
C
f Break out one of the knock-outs in the wall mounted
enclosure.
f Route the bus cable through the aperture from the back.
Installing the wall mounted enclosure
D
1 Flush box
f Secure the wall mounted enclosure to the flush box or to the
wall using the screws provided.
Electrical connection
f Connect the bus cable to the ventilation unit. See the installa-
tion instructions for the ventilation unit.
E
1 Appliance
2 Wall mounted enclosure
3 6-pole socket plug
f Connect the bus cable to the female connector.
6-pole socket plug
1
2
3
4
5
6
f Connect the female connector to the back of the appliance.
Completing the installation
f Carefully push the unit into the wall mounted enclosure until
it engages.
10
| FEB
10. Commissioning
10.1 Appliance handover
f Explain the appliance function to users and familiarise them
with how it works.
Note
Hand over these operating and installation instructions to
users for safe-keeping. All information in these instruc-
tions must be closely observed. The instructions provide
information on safety, operation, installation and main-
tenance of the appliance.
11. Specification
11.1 Dimensions
F
11.2 Data table
Height
Width
Depth
Guarantee
The guarantee conditions of our German companies do not
apply to appliances acquired outside of Germany. In countries
where our subsidiaries sell our products a guarantee can only
be issued by those subsidiaries. Such guarantee is only grant-
ed if the subsidiary has issued its own terms of guarantee. No
other guarantee will be granted.
We shall not provide any guarantee for appliances acquired in
countries where we have no subsidiary to sell our products.
This will not affect warranties issued by any importers.
Not assigned
Environment and recycling
Not assigned
GND
f Dispose of the appliances and materials after use in accor-
+5 V DC
dance with national regulations.
SDA
SCL
f If a crossed-out waste bin is pictured on the ap-
pliance, take the appliance to your local waste
and recycling centre or nearest retail take-back
point for reuse and recycling.
This document is made of recyclable paper.
f Dispose of the document at the end of the ap-
pliance's life cycle in accordance with national
regulations.
FEB
205018
mm
mm
145
mm
www.stiebel-eltron.com
96
31