Télécharger Imprimer la page

Ariston AIF 9.7F AB Mode D'emploi page 17

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 23
MAINTENANCE
Cleaning
Clean using ONLY the cloth dampened with neutral liquid detergent. DO NOT
CLEAN WITH TOOLS OR INSTRUMENTS. Do not use abrasive products. DO
NOT USE ALCOHOL!
Perimeter aspiration panel
Clean the perimeter aspiration panel with the same frequency as the ant-fats
filter, using a cloth and not too concentrated liquid detergent. Do not use
abrasive substances.
Maintenance of the anti-grease filters
Traps cooking grease particles.
This must be cleaned once a month (or when the filter saturation indication
system – if envisaged on the model in possession – indicates this necessity)
using non aggressive detergents, either by hand or in the dishwasher, which
must be set to a low temperature and a short cycle.
When washed in a dishwasher, the grease filter may discolor slightly, but this
does not affect its filtering capacity.
To remove the grease filter, pull the spring release handle.
Maintenance of the charcoal filter
It absorbs unpleasant odors caused by cooking.
The saturation of the charcoal filter occurs after more or less prolonged use,
depending on the type of cooking and the regularity of cleaning of the grease
filter.
In any case it is necessary to replace the cartridge at least every four mounths
(or when the filter saturation indication system – if envisaged on the model in
possession – indicates this necessity).The charcoal filter may NOT be washed or
regenerated.
Assembly
Hook the charcoal filter at the back on the metal tongue of the hood first, then on
the front with the two knobs.
Disassembly
Remove the charcoal filter by turning the knobs fixing it to the hood by 90°.
Replacing lamps
Disconnect the appliance from the electricity.
Warning! Prior to touching the light bulbs ensure they are cooled down.
Replace the old light bulb with the one of the same type as specified in the
feature label or near the light lamp on the hood.
1.
Using a flat head screwdriver or equivalent tool, carefully pry loose the light
cover.
2.
Remove the damaged light and replace it with a new one (see the table
below):
Lamp
Power (W)
20
Voltage (V)
Dimension (mm)
10 (Diameter)
12
22 (Light Center
ILCOS D Code
(according IEC 61231)
HSGST/C/UB-20-12-G4-10/22
3.
Reinstall the light cover. (it will snap shut).
Socket
G4
Length)
17

Publicité

loading