10
Start-up and configuration
Order
Code
number
3.15
SPTch_set1
3.16
SPTch_set2
4.1
C-Pump
ZONE A COOL
4.2
TYPE
ZONE B COOL
4.3
TYPE
4.4
t_T4_FRESH_C
4.5
T4_ca1
4.6
T4_ca2
4.7
SPTcc_set1
4.8
SPTcc_set2
AUTO HEAT
5.1
MAX T4
AUTO COOL
5.2
MIN T4
6.1
ZONE TYPE
SINGLE ZONE
6.2
OPERATION
SET
DUAL ZONE
6.3
OPERATION
SET
ROOM
7.1
THERMOSTAT
SINGLE ZONE
7.2
RT OPERATION
DUAL ZONE RT
7.3
OPERATION
8.1
dTso
8.2
tso
Heat Pump Monobloc Inverter / User Manual
State
Auto climate curve target temp. 1 for
heating
Auto climate curve target temp. 2 for
heating
DC pump standby speed for cooling
Zone A cooling terminal device type, 0=FCU,
1=RAD, 2=FLH
Zone B cooling terminal device type, 0=FCU,
1=RAD, 2=FLH
Refresh time of climate curve for cooling
Auto climate curve ambient temp. 1 for
cooling
Auto climate curve ambient temp. 2 for
cooling
Auto climate curve target temp. 1 for cooling
Auto climate curve target temp. 2 for cooling
Maxmum ambient temp. of auto-heating
mode
Minimum ambient temp. of auto-cooling
mode
Two zones, ONE= single zone, TWO=duan
zone
Single zone target temperature type
Dual zone target temperature type
(2 and 6 for reserved)
Room thermostat type, 0=NON=without
room thermostat, 1=MODE SET, 2=ONE
ZONE, 3=TWO ZONES
Target temperature type on ROOM
THERMOSTAT = MODE SET or ONE ZONE
Target temperature type on ROOM
THERMOSTAT = TWO ZONES
Temperature difference for startup solar
pump
Solar pump running time
Default Minimum
Maximum
35
25
60
28
25
60
3
0
3
FCU
FCU
FLH
FCU
FCU
FLH
30
30
360
25
-5
46
35
-5
46
16
5
25
10
5
25
17
10
17
25
20
29
ONE
ONE
TWO
0
0
3
0
0
7
0
0
3
0
0
1
0
0
3
10
2
20
30
0
90
Setting
Unit
interval
1
°C
1
°C
1
/
1
/
1
/
10
MIN
1
°C
1
°C
1
°C
1
°C
1
°C
1
°C
1
/
1
/
1
/
1
/
1
/
1
/
1
°C
1
MIN
97 / 276 EN