10
Start-up and configuration
10.5.5 AUTO MODE SETTING
Go to
> FUNCTION PARAMETER SET> 5. AUTO
MODE. Press . The following pages will be
displayed
10.5.6 TEMP. TYPE SETTING
About TEMP. TYPE SETTING
The TEMP. TYPE SETTING is used for selecting
whether the water flow temperature or room
temperature is used to control the ON/OFF of the
heat pump.
When ROOM TEMP. is enabled, the target water
flow temperature will be calculated from climate-
related curves.
Go to
> FUNCTION PARAMETER SET >
6. TEMP. TYPE SET. Press . The following pages
will be displayed
Heat Pump Monobloc Inverter / User Manual
10.5.7 ROOM THERMOSTAT
About ROOM THERMOSTAT
The ROOM THERMOSTAT is used to set whether
the room thermostat is available.
How to set the ROOM THERMOSTAT
Go to
> FUNCTION PARAMETER SET >
7. ROOM THERMOSTATSET. Press . The
following pages will be displayed
Notes:
ROOM THERMOSTAT = NON, no
room thermostat.
ROOM THERMOSTAT = MODE
SET, the wiring of room thermostat
should follow method A.
C
ROOM THERMOSTAT=ONE ZONE,
the wiring of room thermostat
should follow method B.
ROOM THERMOSTAT=TWO
ZONES, the wiring of room
thermostat should follow method C
(refer to 9.7.6 "Connection for
other components/- For room
thermostat")
93 / 276 EN