10
Start-up and configuration
Previous No.
parameter
SINGLE ZONE
6.2
OPERATION SET
DUAL ZONE
6.3
OPERATION SET
100 / 276 EN
value
0=set water temp. (manually
adjustment)
1=set watertemp. (weather curve
temp.)
2=for reserved
3=set room temp. (real weather
curve temp.)
1)=0: Zone 1 and Zone 2 are
both water temp. (manually
adjustment)
2)=1: Zone 1 is water temp.
(manually adjustment); Zone 2
is water temp. (weather curve
temp.)
3)=2: for reserved
4)=3: Zone 1 is water temp.
(manually adjustment); Zone 2 is
room temp. (real weather curve
temp.)
5)=4: Zone 1 is water temp.
(real weather curve temp.);
Zone 2 is water temp. (manually
adjustment)
6)=5: Zone 1 and Zone 2 are both
weather curve temp.
7)=6: for reserved
8)=7: Zone 1 is weather curve
temp.; Zone 2 is room temp. (real
weather curve temp.).
use it to set target temperature type when 6.1 ZONE
TYPE = ONE (only one zone)
use it to set target temperature type when 6.1 ZONE
TYPE=TWO (two zones)
Heat Pump Monobloc Inverter / User Manual
function