7.2.5) Level one programming example (ON-OFF functions).
The sequence to follow in order to change the factory settings of the functions for activating "Automatic Closing" (L1) and "Always close" (L3)
have been included as examples.
Tabella 11: Level one programming example
Press the key [Set] and hold it down (approx. 3 s)
1.
Release the [Set] key when L1 LED starts flashing
2.
Press the [Set] key once to change the state of the function associated with L1
3.
Automatic Closing). LED L1 will now flash with long flashes.
Press the [▼] key twice to move the flashing LED to LED L3
4.
Press the [Set] key once to change the state of the function associated with L3
5.
(Always Close). LED L3 will now flash with long flashes.
Wait 10 seconds before leaving the programme to allow the maximum time to lapse.
6.
Once these operations have been completed, LEDs L1 and L3 must remain on to indicate that the "Automatic Closing" and the "Always
Close" functions are active.
7.2.6) Level two programming example (adjustable parameters)
The sequence to follow in order to change the factory settings of the parameters increasing the "Pause Time" to 60 seconds (input on L1
and level on L5) and reducing the "Motor Force" for light gates (input on L5 and level on L2) have been included as examples
Table 12: Level two programming example
Press the key [Set] and hold it down (approx. 3 s)
1.
Release the [Set] key when L1 LED starts flashing
2.
Press the key [Set] and hold it down during step 4 and 5
3.
Wait approx. 3 seconds until LED L3, representing the current level
4.
of the "Pause Time" will light up
Press the [▼] key twice to move the LED which is lit to LED L5,
5.
which represents the new "Pause Time" value
Release the key [Set]
6.
Press the [▼] key four times to move the flashing LED to LED L5
7.
Press the key [Set]; and hold it down during step 9 and 10
8.
Wait approx. 3 seconds until LED L5, representing the current
9.
level of the "Motor Force" will light up
Press the [▲] key three times to move the LED which is lit to LED L2,
10.
which represents the new "Motor Force" value
Release the key [Set]
11.
Wait 10 seconds before leaving the programme to allow the maximum time to lapse.
12.
7.3) Adding or removing devices
Devices can be added to or removed from the ROBUS automation
system at any time. In particular, various devices types can be con-
nected to "BlueBUS" and "STOP" input as explained in the following
paragraphs.
7.3.1) BlueBUS
BlueBUS technology allows you to connect compatible devices
using only two wires which carry both the power supply and the
communication signals. All the devices are connected in parallel on
the 2 wires of the BlueBUS itself. It is not necessary to observe any
polarity; each device is individually recognized because a univocal
address is assigned to it during the installation. Photocells, safety
devices, control keys, signalling lights etc. can be connected to
BlueBUS. The ROBUS control unit recognizes all the connected
16
After you have added or removed any devices, the
automation system must go through the recognition
process again according to the directions contained in
paragraph 7.3.6 "Recognition of other devices".
devices individually through a suitable recognition process, and can
detect all the possible abnormalities with absolute precision. For this
reason, each time a device connected to BlueBUS is added or
removed the control unit must go through the recognition process;
see paragraph 7.3.6 "Recognition of Other Devices".
Example
SET
3s
L1
SET
L1
SET
L3
L3
SET
10s
Example
3s
SET
L1
SET
SET
L3
3s
L5
SET
L5
SET
3s
L5
L2
SET