LOCATION AND INSTALLATION/VENTILATION
LEVELING
The rangetop must be level, especially those models featuring a
griddle. Raise to the desired height by placing shims underneath
the unit as needed.
CAUTION
The appliance top must be level or higher than the adjacent
countertop surfaces. Failure to adjust the height may expose
the adjacent cabinets to excessive heat which may damage the
cabinets or countertop.
INSTALLATION CLEARANCES WITH LOW BACKGUARD
VENT HOOD
18" [45.7]
MIN.
7-1/2" [19] MAX.
OPENING
HEIGHT
G E
RECOMMENDED
2"
GAS SHUT-OFF
[5.1]
VALVE LOCATION
FRONT VIEW
NOTES:
* SHADED AREAS INDICATE WHERE COMBUSTIBLE
MATERIALS ARE NOT ALLOWED.
* APPLIANCE TOP MUST BE LEVEL OR HIGHER THAN THE
ADJACENT COUNTERTOP SURFACES.
* "G" IS GAS CONNECTION ZONE ON REAR WALL. MOUNT
SHUT-OFF VALVE AS HIGH AS POSSIBLE IN THIS ZONE
FOR EASY ACCESS WHEN RANGETOP IS INSTALLED.
* "E" IS ELECTRICAL SUPPLY ZONE.
* "W" IS APPLIANCE OPENING.
* "V" IS MIN. CLEARANCE TO REQUIRED VENTILATION HOOD.
COMBUSTIBLE
MATERIALS
V
W
MIN. CLEARANCE
TO NEAREST
COMBUSTIBLE
SIDE SURFACE
PLATFORM
10"
[25.4]
28-1/2"
[72.4]
9-1/2"
ELECTRICAL
[24.1]
SUPPLY
LOCATION
APPLIANCE
COOKING
SURFACE
APPLIANCE
TOP
12"
[30.5]
28-3/16"
71.6
37-1/8"
[94.3]
TO COOKING
SURFACE
FINISHED
FLOOR
DIMENSIONS IN BRACKETS [ ] ARE IN CM.
RANGETOP
MODEL
KRT304
KRT365
KRT364GD
KRT485GD
KRT484GD
©2019 Hestan Commercial Corporation
(CONTINUED)
COOKING
SURFACE
TOP
REF 1.12"
REF 1.12"
[2.84 cm]
[2.84 cm]
COMBUSTIBLE
MATERIALS
13" [33]
MAX.
LOW
BACKGUARD
24-1/2" [62] MAX.
PLATFORM
28-1/2"
[72.4]
SIDE VIEW
W
V
(MIN)
30" [76.2]
30" [76.2]
36" [91.4]
30" [76.2]
36" [91.4]
30" [76.2]
48" [121.9]
30" [76.2]
48" [121.9]
30" [76.2]
EN
7-1/2" [19]
MAX.
OPENING
HEIGHT
5