Reinstall Nozzle/Check Electrodes
WARNING: Inspect the nozzle adapter before replacing the nozzle. If the threads have been
damaged or shows score marks, replace the nozzle line/adapter assembly.
1. Loosen electrode clamp using 5/16" nut driver, and remove electrodes.
2. Loosen set screw on spinner assembly using 3/32" hex key. Remove spinner assembly from nozzle
assembly
3. Remove nozzle using two wrenches as shown in Figure 3A.
4. Reinstall spinner assembly onto nozzle assembly.
5. Slide electrodes through holes in spinner.
6. Set electrodes to proper gap, using Carlin electrode gauge (see Figure 2B).
7. Tighten electrode clamp.
8. Tighten spinner assembly set screw using 3/32" hex key.
9. To replace the nozzle assembly, reverse the "remove the nozzle assembly" sequence.
NOTE: Use care when tightening the oil line fitting to oil tube extension. Tighten securely, but do
not cross- thread or over-tighten.
Figure 3A : CAREFULLY SUPPORT THE NOZZLE ADAPTER
User's Manual: Radiant Heater
WHEN REMOVING OR INSTALLING NOZZLE
3-3