Télécharger Imprimer la page

Balluff BTL7-V50E-M-A-C003 Serie Notice D'utilisation page 31

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 45
BTL7-V50E-M _ _ _ _ -A/B/Y/Z(8)-C003
Magnetostrictive Linear Position Sensor – Rod Style
3
Construction and function (continued)
3.3
LED display
LED 4
(Link/Activity
OUT)
LED 1
(BTL status)
Fig. 3-3:
BTL7 LED displays
3.3.2
LED 2: EtherCAT status
LED 2
Green
Off
Flashing (2.5 Hz)
Single flash
(1 flash/s)
On
Flickering (10 Hz)
Red
On
Double flash
Single flash
Flashing
Flickering
Off
Tab. 3-2:
LED 2
3.3.3
LED 3 / LED 4: Link/Activity
LED 3/LED 4 (green)
On
Flickering
Off
Inverted double flash
Tab. 3-3:
LED 3 and LED 4
www.balluff.com
LED 3
(Link/Activity
IN)
LED 2
(EtherCAT
status)
Slave status
Error
INIT
PRE-OP
SAFE-OP
OP
INIT
Application error
Timeout of process data
watchdog/timeout of EtherCAT
watchdog
Local error
Invalid configuration
Error during boot-up
No error
Status
Port open
Port open
Port closed
Port closed
(must be opened manually)
3.3.1
LED 1: BTL status
LED 1
Operating state
Green
Normal function
Magnet is within the limits.
Red
Error
No magnet or magnet outside the limits.
Tab. 3-1:
LED 1
Meaning
The device is in the INITIALISATION state
The device is in the PRE-OPERATIONAL state
The device is in the SAFE-OPERATIONAL state
The device is OPERATIONAL
The device is starting and has not yet reached
the INIT state.
A critical application or communication error has
occurred.
The application has exceeded the time limits.
The device has automatically changed the
EtherCat status because of a local error. The
error indicator in the AL status register is set to 1.
General configuration error
An error was detected during the start-up
process. The INIT state has been reached, but
the error indicator in the AL status register is set
to 1.
EtherCAT communication functions without any
errors.
Connection
Yes
Yes
Data is being exchanged
No
Yes
english
9

Publicité

loading