31601 Whispa Manual - US+French.qxp 16/11/2017 12:01 Page 5
®
04
WHISPA III
5000, 7000 & 9000
5.0 Fixing
Before proceeding with the installation, unpack the carton
contents and check against the checklist below:
®
1. WHISPA III
unit.
2. This instruction manual.
3. Grille.
4. Screw fixing kit (with grille).
l A clean and level floor area is required under the cupboard
base.
l Floor mounting - WHISPA III
the floor and the base of the unit is fitted with four mounting
feet.
l Decide the position of the WHISPA III
plinth to the dimensions of Fig. 1 (floor mounting).
Fig. 1 Plinth opening - floor mounting
6.0 Electrical Connection
WARNING: This appliance must be grounded.
l The electrical installation must comply with
local or national wiring regulations.
l This unit is supplied fitted with 8ft of 18awg
cord with plug.
Do not energize the electrical supply until the remaining stages of the installation have been completed.
®
is normally fitted directly onto
®
, mark out and cut the
A
B
Model
A
5000
18
7000
20
9000
22
A = Width of cutout
B = Height of cutout
Note: unit dimensions given in Technical Data section 9.
EN
Dimensions (in)
B
3
/
4
8
1
/
4
2
5
/
4
8