Télécharger Imprimer la page

Annovi Reverberi RK 11.14 N Notice D'utilisation Et Installation page 37

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Inspecting the pump mounting
Check that the pump's fixing screws have not become loose.
If necessary, tighten them with the driving torque stated in the installation design.
Inspecting the connections and pipes
- Inspect the connections for leaks.
Leaks can normally be dealt with by tightening the connections properly.
If leaks from the intake pipeline connections are noticed, the seals must be repaired.
- Inspect the hoses.
If the pipes show signs of aging, breakage, swelling, rubbing, etc., they must be replaced.
Inspecting the Filter
- Inspect the filter cartridge.
If the filter cartridge is fouled or damaged, refer to the filter manufacturer's instructions for details of how to
restore the filter cartridge to its original filtering condition.
Checking the oil level
- Check the oil with the pump level and cold.
- Check the amount of oil through the level gauge (A).
- If necessary, top up with oil with the characteristics specified in
the "Lubricants table".
To top up with oil proceed as described below.
1) Unscrew the plug (B) and pour oil in until it is halfway up the
level gauge (A).
2) Screw on the plug (B).
Changing the oil
Position the machine in which the pump is incorporated
perfectly level, with the pump slightly warm.
Do not release oil into the environment.
Dispose of spent oil in accordance with statutory requirements.
To change the oil, proceed as described below.
1)
Position a receptacle of suitable capacity to collect the spent oil.
2) Unscrew the drain plug (A) and allow all the oil to flow out.
3) Screw on the drain plug A).
4) Unscrew the filler plug B).
5) Pour in the fresh oil through the filler hole until the correct
level is reached (see "Checking the oil level").
6) Screw on the filler plug B).
English
MAINTENANCE INSTRUCTIONS
37
UN003402-CV
UN003403-CV
7
Use and Installation

Publicité

loading