12. MAINTENANCE OF
BRUSHES AND COLLECTOR
Always remove the plug from the mains
socket before carrying out any work on
the machine.
The brush must be replaced when worn out as follows:
Take off the cover (R) (Fig. 1) by removing the four
screws holding it in place.
To change each brush, move the end of the spring (T)
(Fig. 10) backwards and keep it in this position. Remove
the worn brush and replace it with another original
VIRUTEX brush.
Ensure that it slides smoothly within the guide and
release the spring (T) over the brush.
Replace the cover (R) (Fig. 1) with its screws.
If possible, leave the machine running for 15 minutes to
ensure that the brushes are correctly adapted.
Should you detect burns or ribbing on the
collector, have it repaired at a VIRUTEX
technical service outlet.
13. NOISE AND VIBRATION LEVEL
The noise and vibration levels of this device have been
measured in accordance with European standard EN
60745-2-14 and EN 60745-1 and serve as a basis for com-
parison with other machines with similar applications.
The indicated vibration level has been determined for
the device's main applications and may be used as an
initial value for evaluating the risk presented by expo-
sure to vibrations. However, vibrations may reach levels
that are quite different from the declared value under
other application conditions, with other tools or with
insufficient maintenance of the electrical device or its
accessories, reaching a much higher value as a result
of the work cycle or the manner in which the electrical
device is used.
Therefore, it is necessary to establish safety measures
to protect the user from the effects of vibrations, such
as maintaining both the device and its tools in perfect
condition and organising the duration of work cycles
(such as operating times when the machine is subjected
to loads, and operating times when working with no-load,
in effect, not in use, as reducing the latter may have a
considerable effect upon the overall exposure value).
14. WARRANTY
All VIRUTEX power tools are guaranteed for 12 months
from the date of purchase, excluding any damage which
is a result of incorrect use or of natural wear and tear
on the machine. All repairs should be carried out by the
8
official VIRUTEX technical assistance service.
15. RECYCLING ELECTRICAL EQUIPMENT
Never dispose of electrical equipment with domestic was-
te. Recycle equipment, accessories and packaging in ways
that minimise any adverse effect on the environment.
Comply with the current regulations in your country.
Applicable in the European Union and in European
countries with selective waste collection systems:
If this symbol appears on the product or in the accom-
panying information, at the end of the product's useful
life it must not be disposed of with other domestic waste.
In accordance with European Directive 2002/96/EC, users
may contact the establishment where they purchased the
product or the relevant local authority to find out where
and how they can take the product for environmentally
friendly and safe recycling.
VIRUTEX reserves the right to modify its products wi-
thout prior notice.
F R A N Ç A I S
RABOT VARLOPE GR120P
(Voir images p. 28, 29, 30, 31)
1. INSTRUCTIONS DE SÉCURITÉ
POUR LE MANIEMENT DU RABOT
Avant d'utiliser le rabot GR120P,
lire attentivement la BROCHURE
D'INSTRUCTIONS GÉNÉRALES DE SÉ-
CURITÉ jointe à la documentation de
la machine.
S'assurer avant de brancher la machine que la tension
d'alimentation correspond à celle indiquée sur la plaque
de caractéristiques.
Porter des lunettes de sécurité pour travailler avec
cette machine.
Maintenir les mains éloignées de la zone de coupe et
toujours prendre la machine par la poignée avec les
deux mains.
Éviter de couper des clous. Vérifier la surface à travailler
avant de la raboter.