Motor Connectors
ESC Specifications
Input Voltage
Temperature Protection
If the ESC temperature exceeds 110 degrees Celsius, the ESC will enter temperature
protection mode and the LED will blink. Once the ESC has cooled down it will resume
normal operation.
Problem and LED Indi-
cator
Motor won't operate. LED
flashes slowly short single
pulses.
Motor won't operate.
LED flashes quickly with
short single pulses.
OM
2-in-1 ESC and Receiver Unit
Battery Wire
Power
Switch
2S LiPo (7.4v)
Throttle Setup
Do not move the throttle when switching the model on as the ESC will
automatically set the throttle neutral.
TROUBLESHOOTING GUIDE
Error Mode
LVC has been
activated.
The ESC is in
thermal shutoff
mode.
www.modellmarkt24.ch
CH3 socket
Possible Causes
Battery voltage is
below the LVC setting.
The ESC is taking too
much load.
19
Steering
(CH1) socket
BEC Output
6.0v/3A Max
Solution
Verify the battery is charged.
Turn off the ESC and allow it to
cool before resuming operation.
Consider making changes to gear
ratio to reduce load to the ESC.