• Use only manufacturer authorized parts. User assumes all risks and liabilities
when using parts that do not meet the minimum specifications and safety
devices of the spray gun manufacturer.
exPloSion Protection iDentification
x markinG:
the spray gun corresponds with ex ii 2G x and is, in accordance with
Directive 2014/34/eu, suitable for use in explosion-hazardous areas—as
of type Zone 1. under certain circumstances, the unit itself may cause the
Zone 1 condition to be in effect.
any static-electricity discharge from the spray gun is to be diverted to the
grounded high-pressure pump via the conductive high-pressure hose as
stipulated.
the maximum surface temperature corresponds to the permissible
material temperature. this and the permissible ambient temperature can
be found in the technical Data.
To avoid the generation of machine sparks, prevent impact stresses and any
work on the unit with tools in the explosion-hazardous area.
reSiDual riSkS
Residual risks are risks, which cannot be excluded, even when equipment is
used for the intended purpose.
In such cases the applicable areas of the actual residual risks will be pointed out
using warning and/or prohibition signs.
risk
Source / cause
Injection
Atomized, high
injury
pressure stream
of fluid
Explosion
Static electricity
or fire
or sparks
Hazardous
Hazardous vapors
vapors
from spray
material
4
impact
Preventative
measures
Severe
NEVER aim the
injury or
gun at any part of
amputation
the body
Severe injury
Use well
ventilated area
Ground the spray
gun
Severe injury
Use well
ventilated area
Use mask
can occur
during:
Setup,
Operation
Operation
Operation