Installation and Servicing
PREPARING TO INSTALL THE APPLIANCE
PREPARING TO INSTALL THE APPLIANCE
Installation rules
- This appliance has been designed for installation in a residential setting.
- Installation must be carried out in accordance with good industry
practice, and with the standards in force in the country of installation.
-
The appliance must be connected to a 230 V / 50 Hz single-phase
power supply.
- Connection must be made in a way that allows complete isolation
of the electrical supply such as a double pole switch having a 3mm
(1/8") contact separation in both poles. The means of isolation must
be accessible to the user after installation. A fuse is required based on
the rating of the appliance.
-
In wet environments such as bathrooms and kitchens, the connection
box must be installed at least 25 cm from the floor. The installation
must be equipped with a 30 mA protective residual current device.
Keep the appliance out of the way of any air currents that
might disrupt its operation
- The appliance must be installed in such a way that the switches and
other control devices cannot be accidentally touched by anyone
in the shower or bath.
-
Installing an appliance at altitude causes an increase in the air outlet
temperature (10 °C per 1000 m change in altitude). It is highly inadvisable
to fit appliances above an altitude of 1000 m (risk of malfunction). The
appliance is not for use above altitude of 2000m.
-
It is prohibited to fit a vertical appliance horizontally, and vice-versa.
- Maintain the minimum distances from furniture when positioning
the appliance. Do not install shelves above vertical appliances.
Do not install it directly under a power outlet.
As the appliance is heavy, we recommend that
two people perform installation.
Do not use the wheel to lift the appliance.
(e.g.: under a ventilation system, etc.).