Contents
Handbook purpose
1.
2.
Norms for general use
3.
Machine identification
4.
Installation
5.
Refigerating connection
6.
Condensate drain connection
7.
Electrics installation
8.
Technical data
9.
Maintenance and cleaning
10. Disposal
11. Failures and solutions
12. Optional items
1.
HANDBOOK PURPOSE
This handbook is issued in order to assist an operator properly to bring the unit cooler on stream ,
give explainations about the relevant safety norms in force within the European Community and
avoid any risks that may be caused by a wrong usage.
NORMS FOR GENERAL USE
2.
For a correct and safe use of the machine, it is necessary to follow the prescriptions present in this
manual as it gives instructions and information about :
installation
use
maintenance
disabling and disposal
The manufacturer cannot accept any liability for damages resulting from failure to follow the
prescriptions and advice given in this handbook.
Read carefully labels placed on the machine, do not cover them for any reason and replace them
in case they are damaged .
Keep this manual carefully.
The manufacturer may review this manual at any time, without notice.
The unit coolers are designed for the use in industrial and commercial refrigeration application for
stable cold rooms. They are not intended for any other purpose. Any other use is to be considered
improper and dangerous .
When the package is removed, please check that every part of the machine is intact; if not,
contact the retailer immediately .
It is forbidden the use of the machine in environment with presence of inflammable gas or where
there is a risk of explosion.
Do not clean the machine with direct water jet, under pressure or with improper substances .
Do not use the machine without its protections ( housing and grid)
Do not expose the machine to heating sources
In case of fire use a powder fire extinguisher
Packaging material must be suitably disposed of according to the low in force
3.
MACHINE IDENTIFICATION
All the machines are equipped with an identifying label (the position of the label is shawn in
Drawing 1) where the following data are quoted :
code
no. of fan motors - no. of
revolutions(RPM)
Watt absorption (W)
Ampere absorption (A)
Power supply voltage (Volt/Ph/Hz)
defrosting:
heaters number
ENGLISH
pag. 13
pag. 13
pag. 13
pag. 15
pag. 16
pag. 16
pag. 16
pag. 19
pag. 19
pag. 21
pag. 21
pag. 21
Watt absorption(W)
power supply voltage (Volt/Ph)
refrigerant group: Group 2(*)
PS pressure (max working pressure)
TS temperature (min. operating temp.)
serial number
RDF Pag. 13