ELX-2
1
Bracket Mounting
Typical installation is shown. It may be necessary to repair the wall
after mounting. The fixture may not cover all of the wall modifications.
Mounting height per structural rough-in dimensions.
10½"
(267)
D
Install trap cover bracket by lining up the locating
notch on the trap cover bracket to the vertical line.
Line up the top of the trap cover bracket to the
horizontal line. Secure the brackets to the wall
anchors using fasteners per the structural rough-in
requirement (supplied by installer). (2x)
10
Locating Notch
B
Using the location notches on the wall bracket,
draw a vertical line down at least 12".
C
Measure down 10½" from the bottom of the
wall bracket and draw a horizontal line.
Locating Notch
3/2/2020
16"
(406)
min.
C
L
Bradley • 215-1807 Rev. F: ECN 19-08-037F
Installation
Install wall bracket to wall
A
per structural rough-in
dimensions. Check to
ensure the bracket is
level. Example anchor
locations shown.