5.4 Preparatory work before
installation
5.4.1 Attaching the support
Different types of supports are available (9
Accessories, page 27). Choose the most suitable
installation and follow all indications in this chapter.
Take special care when attaching and
fastening down the apparatus. If it is to be
attached to a concrete surface you must
use dowel pins with a traction torque rating
of at least 300dN each. For a metal surface
use screws with a diameter of at least 8mm
and of an appropriate length. The clamping
system must be able to support at least 4
times the weight of the entire equipment,
including P&T, lenses and camera.
The device should be assembled vertically.
Any other position could impair the
performance of the appliance.
5.4.2 Cables management
The connection cables should not be
accessible from the outside. It is necessary
to fasten the cables securely to the column
in order to prevent excessive weight pulling
them out accidentaly.
You must use cables suited to the type of
installation.
Insert the cables into the support so that they
protrude by about 50cm.
50cm
Fig. 3
10
6 Assembling and installing
The assembly and installation must be
performed only by skilled personnel.
This is a Class A product. In a domestic
environment this product may cause radio
interference. In this case the user may be
required to take adequate measures.
6.1 Installation
Never, under any circumstances, make
any changes or connections that are not
shown in this handbook. Failure to follow
the connection instructions that are given
in the handbook may create serious safety
hazards for people and for the installation.
Do not change the wiring in the product
as it is supplied to you. Failure to follow
this instruction may create serious safety
hazards for people and for the installation,
and will also invalidate the guarantee.
Keep a connection diagram for future
reference.
6.1.1 Connecting the cables to the base
Insert the cables into the cable glands and, holding
the base at about 20cm from the support, lock the
cable glands with a torque wrench setting of 5Nm.
The cable glands are suitable for cables with a
diameter between 5 and 10 mm.