Model
Handle
I.D.
Type
2130XP
pistol
2130XP-2
pistol
Model
Forward
I.D.
ft•lbs (N•m)
25 to 350
2130XP
(34 to 474)
25 to 350
2130XP-2
(34 to 474)
Tested to ISO8662-7
Tested in accordance with ISO 15744 (Pneumatic tools)
Measurement uncertainty of the Sound Pressure Level 'Kpa' = 3dB(A)
Measurement uncertainty of the Sound Power Level 'Kwa' = 3dB(A)
When the life of the tool has expired, it is recommended that the tool be disassembled,
degreased and the parts be separated by material so that they can be recycled.
Form P7681 Edition 2
SPECIFICATIONS
Drive
2
in
1/2"
1/2" Extended
Anvil
Recommended
Torque Range
Reverse
ft•lbs (N•m)
602 max.
(816 max.)
602 max.
(816 max.)
SAVE THESE INSTRUCTIONS. DO NOT DESTROY.
Inlet Connection
Impacts / min.
(Thread)
bpm
1,200
1,200
Impacting Sound
Level dB (A)
Pressure
Power
( Lp)
( Lp)
94.3
105.3
94.3
105.3
SOURCE/DATE CODE
(Dwg. TPD188)
4
Minimum Inside Ø
(Air Hose)
NPT
in. (mm)
1/4
3/8 (10)
1/4
3/8 (10)
Free Speed Sound
Level dB (A)
Pressure
Power
( Lp)
( Lp)
90.8
101.8
90.8
101.8
LOCATION
Vibrations
Level
2
m/s
4.6
4.6