EN | EVO - EVOK | User and Maintenance Manual
ASSEMBLY
Proceed with the previous instructions, but in the inverse order. To facilitate the operations we further advise
(only for the EVO version), removing the lateral insulating glass of the display case as described below:
12)
Remove the front panel, unscrewing the 2 screws that fasten it located on its back profile.
13)
Allow the curved front insulated glass to slide out, in its guide rail, to allow the extraction of the right
and left side insulated glass.
14)
Then hook the rods at the sides of the lid to the side stanchions, as shown in the figure. Be sure that the
joints meet perfectly.
15)
Reassemble the insulated glass sides, being careful to not scratch or break them (13 B).
16)
Realign the front curved insulated glass, letting it slide along its lower rail (13 A).
17)
Reassemble the front panel (12).
5.4 REPLACE OF TOP CANOPY AND SHELVES LIGHTINGS
To replace the lamps it is always necessary to disconnect the power cord or open the switch
upstream of the connection of the Refrigerator unit.
If the unit is equipped with lamps, in case of breakage they must be replaced with others of the same power.
Check the data on the plate to the side of the lamp.
This data indicates the power absorbed by the lamp.
To replace the lamp, remove the plug, release the lamp to be replaced and reconnect and clasp the new lamp.
5.5 MOTOR FAN REPLACEMENT
If the equipment is provided with fan, and you need to replace it, removing the power supply, checking the data plate
of the motor fan and replace it with one of with same power, voltage and frequency.
These operations must be done by a technician!
5.6 COMPRESSOR / REFRIGERANT GAS REPLACEMENT
In the case of damage and / or replacement of the compressor, recover the refrigerant gas and the oil avoiding
dispersion in the environment.
The repalcement must be done by a technician!