ATTENTION
In order to allow a good functioning of the equipment please pay attentions to the following instructions:
• Do not place the unit in an area directly exposed to sun light or to other heating sources, such as
high intensity incandescent lighting systems, ovens or other radiant heating sources, e.g. heating radiators etc.
• Do not place the unit nearby door openings producing air currents, whether doors or windows
or directly exposed to air from fans, vents or fan coil unit air conditioner.
• Do not block or obstruct the air inlets of the built-in refrigeration unit.
• Do not place any objects on the unit, including boxes or any other type of objects; leave the entire
perimeter of the unit completely free so that air can circulate properly.
•
Do not place the equipment inside areas with high relative humidity levels (it may cause formation of condensation)
• Do not place the equipment inside a closed niche, as there is not enough air circulation and may
cause the refrigeration unit to not work properly.
• Do not place the unit one above another.
• Verify that the room in which the equipment is placed must be sufficiently aired, even when the shop is closed.
Verify that in the installation room there is enough air turnover, even during closing and rest hours. In
this way the expansion/condensing unit will work correctly.
INSTALLATION MINIMUM DISTANCE
In order to allow a good performance of the cabinet, during the installation you must respect the MINIMUM WALL
distances as showed on the drawings.
1.6 WATER CONDENSATION DRAIN /WATER DRAIN CONNECTION
The Close Multideck Display with built-in unit is fitted with automatic evaporating water condensation tank with
sponge. Verified that the water pipe is correct positioned and periodically and the basin is must be cleaned from waste materials.
The Close Multideck Display with remote unit, not having the basin for water collection is provided with
a siphon only, the customer take care of the water connection pipe. Its connection to the principal basin prevents the
circulation of cold air and of bad smells. The Close Multideck Display cannot absolutely be installed without
siphon and each drain must have its own siphon. It is necessary to have the drain-siphon after the exit of belly section
to block the out-take air and also to avoid any smell. You never install the Close Multideck Display without siphon and to
connect more drains of the same Close Multideck Display together. Each drain must have only one siphon.
1.7 CLOSE MULTIDECK DISPLAY WITH BUILLT - IN UNIT
If the Close Multideck Display is fitted with built-in condensing unit, keep it clear all around in line
to not obstructs air circulation. Do not put any cartoons or any others materials that could obstruct the
air ventilation on all sides of the Close Multideck Displays.
For good performance of the Close Multideck Display, do not obstruct the condensing unit ventilation.
Air suction grid and air delivery grid positioned on the front and back sides of the Close Multideck Display must be always opening.
Check if the room is sufficiently aired, even when the shop is closed. Avoid to obstruct the sources of air
placing objects along the perimeter of the Close Multideck Display. It is necessary to place Close Multideck
Displays at least five centimetres from the wall. Check if the foot board obstructs air circulation. Before acti-
vating electric connection clean the Close Multideck Display completely by using tepid water and
neutral detergents (non-aggressive) . Dry it with a smooth rag.
EVO - EVOK | User and Maintenance Manual | EN
29