EN | EVO - EVOK | User and Maintenance Manual
1.8 CLOSE MULTIDECK DISPLAY FITTED FOR REMOTE
CONDENSING UNIT
The electrical and cooling connection must be done only from a qualified technician. We recom-
mend to follow the electrical norms in force.
The equipment engine designed for remote refrigerating unit must be protected from atmo-
spheric agents. You must leave free space all around the remote unit. Respect the spaces between the unit
and the walls or others obstacles, in order to have a good air ventilation to avoid a good performance and easy
maintenance during the cleaning of the condensing unit. It is necessary to remember that higher room tempe-
rature and insufficient air circulation around the condensing unit imply higher energy costs and worse technical
performances of the refrigerator, with a possible waste of the exposed goods.
2 ELECTRICAL CONNECTION AND EARTHING
2.1 ELECTRICAL POWER SUPPLY
The installation and the electrical connections must be carried out in conformity with
the electrical rules in force. These operations must be carried out by qualified staff.
The Company declines any responsibilities originated from the no observance of the above rules
in force.
See the equipment electric diagrams at the end of this manual.
Before plugging in the equipment, it is necessary to proceed with its complete and careful clea-
ning, using warm water with no aggressive detergents and drying with a soft cloth all the humid
parts (read with attention the chapter "3 CLEANING" Pag. 32).
In order to carry out a correct plug in you must proceed as follow:
1.
Before the connection to the electrical supply it is necessary to verify that the frequency / tension of
the line correspond to those written on the identification label of the Close Multideck Display
(APPENDIX - Product identification plate). A variation +/- 10% of the nominal rated voltage is permitted.
It is needful to connect the equipment to an efficient ground socket
2.
It is advisable to install an bipolar sectioning switch with opening of contacts at least 3 mm
wide at the source as for example automatic switch, fuse wire (the fuse screw must be removed from the
socket) switch for fault current and electricity meter.
3.
In order to save the equipment from overload or short circuit, the connection to the electricity
has to be done through a magneto-thermal switch high sensibility (30 mA) with manual re-
establishment, of the right power.
4.
For protective device size, consider the power consumptions showed on the identification label
of the equipment ("APPENDICE - 1" Pag. 90)
5.
It is necessary that the connection cable section is commensurate to the power consumption
of the unit.
6.
The law requires that the unit is earthed; therefore it is necessary to connect it to an efficient
earth connection.
( EARTH CONNECTION)
30