7.2 SETTING THE CONTACT FOR LIMIT SWITCHES
Default: No limit switches
This procedure is used to set the type of contacts of limit switches.
PROCEDURE
STEP 1
With a paper clip makes a long press of the "hidden" button.
The LED turns on light blue/pink/yellow cyclically.
Release the key when the led is light blue.
STEP 2
Press the button 1 on the receiver for a short time and count the number of Flashes
emitted by the LED:
FLASHES
FUNCTION
NUMBER
1
No limit switches
2
NC contact
3
NO contact
4
Management with radio position sensor *
STEP 3
Press the button for a short time during the Flash that corresponds to the function
desired to end the count. The led turns off
* the position sensor is an accessory that must be purchased separately
x1
ACTION: Short press of button 1
LED: Count the number of Flashes
x1
ACTION: Short press of button 1
LED: Turns off