ENGLISH
Please read the following instructions thoroughly and check the Energiser User Manual
before starting assembly!
Included in the delivery of a Vandal-Proof Box without energiser
Vandal-Proof Box with fence lead connector cable + special earth stake
Hardware bag: 1 User Manual
1 Hexagon socket wrench SW 5
2 Insulated Keys
1 Door contact switch
1 Connecting cable (red, eyelet Ø 6 mm, tin-plated cable head)
3 Rubber grommets (small)
3 Screws M6*16
1 Screw M6*20
1 Washer 6*20
3 Vulcanised fibre rings Ø 6 mm
7 Nuts M6
1 Locknut M6
Operating instructions for Vandal-Proof Box
Over many years the idea of protecting the energiser, the battery and, if necessary, the solar
panel by using the high voltage pulse they produce has been tried and tested. An unauthorised
person touching the box or the frame of the solar panel will receive a very uncomfortable and
deterring electric shock. Only the owner can activate or deactivate the box by using an insulated
key. The box is anchored to the ground with an earth stake approx. 1 m long.
Installing the energiser in the box
Plug the battery lead cable into the power input socket on the rear of the energiser, and guide it
to the outside through the cable outlet located on the upper right-hand side of the energiser (front
view). Insert the screws M6*16 in both of the top outer bolt slots on the rear of the energiser
housing. Secure each one with a nut and tighten firmly. All three upper bolt slots must be used for
fastening the P4500 and the P4600. Please make sure that each screw fits entirely into the bolt
slot. The screw M6*20 serves as the lower mounting fixture. It must also be inserted in the desi-
gnated bolt slot and together with the eyelet of the connecting cable must be secured with a nut,
in order to form a mounting bolt. Then connect the small red cable to the red fence output termi-
nal of the energiser. Install the now-prepared energiser to the inside back wall of the box. Prior to
this, push the black rubber grommets into the screw holes that are not needed. When facing the
box, the energiser hangs vertically with the fence output terminal on the right side.
9