7.
Technical data
7.1
General specification
Parameter
Specification
Safety standards
IEC/EN 61851-1
Certification
1-phase, 3-phase
IP classification
IP54
IK classification
IK10
Directives and stand-
LVD 2014/35/EU, 2014/30/EU, 2015/863/EU,
ards
2014/53/EU, PN-EN IEC 61851-1: 2019-10, EN
IEC 61851-1: 2019, PN-EN IEC 61851-21-2: 2021-
09, EN IEC 61851-21-2: 2021, PN-EN IEC 61439-
7:2020:10, EN IEC 61439-7:2020, PN-EN IEC
62196-1: 2023-07, EN IEC 62196-1: 2022, PN-EN
IEC 62196-2: 2023-07, EN IEC 62196-2: 2022, PN-
EN IEC 63000: 2019-01, EN IEC 63000: 2018
•
HOME BASIC / HOME RFID: 2.8 W
Power consumption
•
CLUE: 2 W
•
IOT: 4 W
•
BUSINESS PREMIUM: 4,5 W
7.4
Compliance of protective device
7.4.1
Compliance of protective devices (IEC models)
Requirements
Dedicated advance safety device
Advance overcurrent circuit breaker (e.g., residual current circuit break-
er with overcurrent protection or overcurrent circuit breaker)
Note: The rating of the circuit breaker depends on the diameter and
length of the cable, rated values of EVSE, and environmental parame-
ters (to be determined by the electrician).
The circuit breaker serves as the main switch for EVSE.
Advance residual current circuit breaker.
7.5
Wall requirements
Parameter
Specification
Wall thickness
Minimum 89 mm
Wall material
The mounting surface must be flat and stable, e.g. a finished brick or concrete wall.
Wall strength
The wall must be suitable for the components listed below:
EVSE weight. Section 7.3, Torque for mounting screws. Section 7.10
7.6
Dimensions
7.6.1
AC input with socket, type 2
7.6.2
cable
24
7.2
Environmental conditions
Parameter
Specification
Storage temperature
From -40°C to +50°C *
Working temperature
-40°C to +50°C *
Storage conditions
In a dry room
Working height
Below 2000 m above sea level
* range for the Business Premium version:
Storage temperature -40 to +50°C
Operating temperature -25 to +45°C
7.3
Weight
EVSE type
Weight [kg]
HOME BASIC / HOME RFID
AC wall mounted, type 2 with sock-
4.6 kg
et and cable (IEC models)
6.0 kg
CLUE
AC wall mounted, type 2 with sock-
4.8 kg
et and cable (IEC models)
6.4 kg
IoT
AC wall mounted, type 2 with sock-
5.3 kg
et and cable (IEC models)
6.9 kg
BUSINESS PREMIUM
AC wall mounted, type 2 with sock-
5.0 kg
et and cable (IEC models)
6.6 kg
Specification
Options:
•
Residual current circuit breaker (type A) with overcurrent component.
•
Residual current circuit breaker (type A) with separate overcurrent protection.
Circuit breaker ratings:
•
40A for EVSE with a rated current of 32A.
•
20A for EVSE with a rated current of 16A.
Circuit breaking characteristics: type C
At least Type A, with a rated residual current
max. 30 mA.
Note: EVSE features a DC leakage current monitoring system > 6mA.
AC input with
7.6.3
Space requirements for
EV charging cable
installation
Z1
EVSE
Z2
Parameter
Specification
[mm]
Z1
>250
Z2
800-1500
7.7
AC input specification
7.7.1
General specification
Parameter
Specification [mm]
Network layout
TN-S, TN-CS
Frequency
50 Hz
Overvoltage category
Category III
Protection
Overcurrent, Overvoltage,
Earth fault, including
the flow of direct current
Required external
surge protection.
7.7.3
230 VAC, 1-phase (IEC models)
HOME BASIC / HOME RFID
U1 – 230 VAC, maximum 264 VAC.
230 VAC, 1-phase (IEC models)
CLUE
U1 – 230 VAC, maximum 264 VAC.
7.7.4
AC input specification (IEC models)
Parameter
Specification [mm]
Input voltage (3 phases)
400 VAC
Input voltage (1 phase)
230 VAC
Input connection
1 phase or 3 phases
AC power supply
Power consumption
maximum 2.8W
In standby mode
Protection against
6 mA DC
current leakage to earth
Maximum input power
11 kW (16 A)
(3-phase)
22 kW (32 A)
Maximum input power
3.7 kW (16 A)
(1-phase)
7.4 kW (32 A)
7.7.2
400 VAC 3-phase with neutral conductor (TN) (IEC models)
HOME BASIC / HOME RFID
U1 – 230 VAC,
maximum 264 VAC.
U2 – 400 VAC,
maximum 460 VAC.
400 VAC 3-phase with neutral con-
230 VAC, 1-phase (IEC models)
ductor (TN) (IEC models)
CLUE
BUSINESS PREMIUM
U1 – 230 VAC, maximum 264 VAC.
U1 – 230 VAC, maximum 264 VAC.
U2 – 400 VAC, maximum 460 VAC.
400 VAC 3-phase with neutral con-
230 VAC, 1-phase (IEC models)
ductor (TN) (IEC models)
IOT
BUSINESS PREMIUM
U1 – 230 VAC, maximum 264 VAC.
U1 – 230 VAC, maximum 264 VAC.
U2 – 400 VAC, maximum 460 VAC.
400 VAC 3-phase with neutral conductor (TN)
(IEC models)
IOT
U1 – 230 VAC, maximum 264 VAC.
U2 – 400 VAC, maximum 460 VAC.
25