Télécharger Imprimer la page

Frigidaire FHWH184WB2 Instructions D'installation page 2

Masquer les pouces Voir aussi pour FHWH184WB2:

Publicité

Les langues disponibles

Les langues disponibles

4. Check for anything that could block airflow
Check area outside of window for things such as shrubs, trees, or awnings. Inside, be sure furniture, drapes, or blinds
will not stop proper air flow.
5. Check the available electrical service
Power supply must be the same as that shown on the unit serial
nameplate. (See Use & Care Guide for serial plate location.) Power
cord is 48" long. Be sure you have an outlet near.
All models have a 3-prong service plug to provide proper service and
safe positive grouding. Do not change plug in any way. Do not use an
adapter plug. If your present wall outlet does not match your plug, call
a qualified electrician to make the needed change.
6. Carefully unpack air conditioner
Remove all packing material. Protect floor or other stable flat surface
with covering to prevent scratches from unit. With the aid of an
assistant, remove unit from styrofoam base and rest on protected
surface. Move and install unit with the aid of an assistant. Save
packing and shipping box for future unit storage.
Accessory Kit includes
Hardware bag(shipped inside
window support brackets)
Window support bracket (2)
Side retainer (2)
Window Filler Panel (2)
MEDIUM models only
HEAVY DUTY top angle rail can be found in carton base
packaging (FIG.3)
a large flat blade screwdriver
adjustable wrench or pliers
level
Phillips screwdriver
Hardware ( in plastic bag)
7/16" Locking Screw and Flat
Washer for window filler panels
1/2" Long hex head screw
Safety Lock
1/2" Long Screw
and locknut
3/4" Long Flat Head Bolt
and Locknut
foam insert
2
Installation Instructions
Foam gasket
Window sash seal
Bottom rail seal
Cabinet seal
Top angle rail
Tools Required
tape measure
pencil
Socket wrenches
HEAVY DUTY
TOP ANGLE RAIL
Qty.
Hardware ( in plastic bag)
2 set
Sill Angle Bracket
Long hex-head locking screw for top
7
angle rail, side retainer 5/16" long
1
(for Vinyl-Clad window)
4 set
2 set
2
Avoid fire hazard or electric
WARNING
shock. Do not use an extension cord or an
adaptor plug. Do not remove any prong
from the power cord.
115V
230V
15A
15A
Grounding Prong
Do not, under any
circumstances, cut,
230V
30A
remove or bypass the
grounding prong.
Safety Lock
weather seals
(6"X3/4"X1/12")
Grounding wire and
#M4x8-Z screw
230V
20A
FIG.3
Qty.
2
10
2
2
5
1 set

Publicité