IMPORTANT! Any installation operation shall be carried out by a suitably trained
staff, following carefully the information given in this manual.
Check the packaging at the reception of the goods and store only at a dry place. Verify that the device
has not been damaged during transport or storage operations. Make sure you receive all the compo-
nents. Ask the manufacturer for any possible missing component.
The hose reel has to be wall mounted at a minimum height of the floor of 2.50 m in order to
prevent accidents during work operations. Considering the hose reel weight and dimensions, its
movement requires the use of lifter devices.In particular cases it is possible to mount it on the floor or on
other machines as accessory, only if complete with a fixed support. The hose-guide arms can be fixed in
three different positions according to the hose reel installation (see pictures A-B-C
IMPORTANT! Models for distribution of Oil 60 bar (1") only allow the installation on position A - B.
Mount the hose reel in fixed position on stiff and consistent walls using 4 dowels of 10 mm diameter.
(See drawing p.28)
WARNING! The manufacturer declines any responsibility for injuries to people or damages to
things caused by a wrong assembly of the hose reel.
Always connect the hose reel to the line by the couplers and the flexible hose suitable for this use,
above all in case of high pressure and temperature. To avoid consequent loss of fluid tighten the
fittings using appropriate keys, keep back the swivel joints to avoid damaging them.
According to the rules, put a ball-tap on the feeding line of the hose reels in order to make the maintenance
operations easier. The said ball-tap can be used as a safety valve for dangerous situations.
The connection hose is supplied as standard for models with swivel joint in composite materials.
9.1) Diesel fuel/Water 90°C (3/4"-1"): Tighten the swivel joint on the hub, fit the lateral cover and tighten
the elbow on the swivel joint using a suitable sealant.
9.2) Urea/Water 50°C (3/4"-1"): Mount the lateral cover and hand-tighten the swivel joint, insert the hose
into the hose connector and fix it with the clamp.
IMPORTANT: Do not use sealants.
9.3) Oil (3/4"-1"): Tighten the swivel joint on the hub, fit the lateral cover and tighten the elbow 90° on
the swivel connector.
9.1
IMPORTANT! For versions that mount hoses manufactured with materials suitable for
water passage for contact with food, before use carry out an adequate washing flow
of the parts in contact with the fluid.
8 - INSTALLATION
9 - LINK
9.2
- 11 -
p.28
).
9.3