Operation
5
Operation
Button
* Only version with data logger
5.1 Display Mode
Start sequence:
1. Serial number display
2. Switching to display mode
3. Display of the current measurement
Zero point suppression:
Type E2: 0.2 % of the range ( p. 28)
•
Types D2 and C2: 0.1 % of the range ( p. 28)
•
Pressure range exceeded /
Condition:
Pressure ≥ 110 % of the pressure range (FS)
•
Return to normal display when the pressure drops again
•
If
is displayed in a depressurised state, there is a malfunction.
oFL
Please contact SIKA.
Zero point correction (ZERO)
Correct deviations in depressurised state (atmospheric pressure).
IMPORTANT
Only use at atmospheric pressure.
Activation under pressure leads to incorrect measurements.
•
- 22 -
1. function
Switch on/off
Display MIN, MAX or full scale
value (FS)
Correct zero point
Delete MIN/MAX, confirm
display
oFL
2. function
(press for 2 s)
Switch on the backlight (20 s)
Set date and time*
Open Settings
Start/stop data logger*
© SIKA • Ba_Ref-E2D2C2 • 07/2024