Speedaire Operating Instructions and Parts Manual
Speedaire
Typical mounting position
E
E
N
N
G
G
L
L
I
I
Floor Mounting
S
S
General Safety Information
H
H
1. Read the following precautions and
instructions before you begin assembly or
start using. Failure to comply with these
instructions could result inpersonal injury
or property damage. Keep these
instructions in a convenienct location for
future reference. The information
contained in this instruction manual will
help ensure many years of trouble free
operation. Please take a few moments to
read through this instruction manual
before installing your new hose reel.
2. Make sure the line pressure does not
exceed the rated operating pressure of
hose reel, refer to the specifications
3. Exposure of the skin directly to
pressurized air or fluid could result in
severe bodily injury.
4. Before carrying out any maintenance
turn off and disconnect the supply line
to the reel and carefully release the
hose line presure.
5. Use soap and water when checking for
leaks.
Installation
1. For overhead ceiling mounting : Install
reels at least 10 feet above the floor.
2. You will need to purchase appropriate
hardware for mounting your new reel.
3. The reel base has four 1/2" drilled holes
for mounting on a suitable flat surface.
4. Your reel has both angle adjustable
hose roller guides.
To adjust the angle of the roller guides.
a. Loosen the bolts on either side of
the roller guide.
b. Adjust the guide to the required angle
c. Re-tighten the bolts
5. Using the four holes in the base, mount
the reel in the desired location.
Industrial Hose Reel
®
Wall Mounting
Be sure to use appropriate hardware
and tighten securely.
6. Apply PTFE tape or pipe sealant to
supply line threads, attach to reel inlet
and tighten. The other end of incoming
line can now be connected to desired
supply source. Tighten stopper bolts and
unlatch the reel.
7. Apply PTFE tape or pipe sealant to outlet
fitting on reel hose, then attach to desired
tool, or nozzle. Check connection for
leakage, also check hose reel for correct
operation.
8. If hose stopper adjustment is required, pull
hose from reel and allow to latch at
desired length. Loosen stopper bolts and
slide stopper to a position close to the
hose guide. Re-tighten stopper bolts and
check operation.
To avoid damage,
please check the connection parts and hose
assembly in good condition prior to use.
Operation
1. Check reel for correct operation by
slowly pulling out the hose. A "clicking"
noise will be heard every half revolution
of the drum.
2. To latch the reel, pull out the hose and
allow it to retract after hearing the first,
second or third "click".
3. To unlatch, slowly pull out the hose until
the "clicking" noise stops, then let the
hose retract until the hose stop rests
against the hose guide.
To avoid damage to the
reel or personal injury always hold on to the
hose while it is rewinding.
2
31XG62, 31XG63, 31XG64, 31XG66,
31XG67, 31XG68 & 31XG70
Ceiling Mounting
Maintenance and Repair
If reel will not wind hose completely, it
may be necessary to adjust spring's
tension.
Adjust Spring Tension
1. Pull out approximately 6ft of hose and
allow the drum to latch.
2. Remove hose stopper from hose and
feed hose back through the guide.
3. Wrap the hose one rotation around the
drum to increase tension or unwrap the
hose one rotation to decrease tension.
4. Re-insert hose through guide and install
stopper onto the hose end.
5. Unlatch the drum and check tension. Pull
hose from reel and adjust stopper position
if necessary.
Replacement of Swivel Seal
(See Below Figure No. 01)
1. Turn off air/water supply and carefully
release pressure in hose.
2. Disconnect supply line from swivel inlet.
3. Remove snap ring and swivel housing
from reel axle.
4. Replace the seals and reassemble swivel
housing.
5. Reconnect inlet supply line.
6. Check all connections for leaks
(Swivel Housing)
Snap ring
Reel Axle (Shaft)
Reel Axle (Shaft)
Oring
Figure No. 01