AXOVIA 3S io
3.4
Unlocking and locking the motor
Unlocking
1
3
1] Lift the sealing cap.
2] Unlock the upper cover.
3] Remove the upper cover.
4] Unlock the motors by turning the button to the unlocked position.
CAUTION
Do not forcibly push the gate. Hold the gate over its entire travel during
manual manoeuvres.
Locking
1
2
1] Close the gate.
2] Push on the arms to lock them.
3] Lock the motors by turning the button to the locked position.
CAUTION
The drive must be locked before any new command.
Copyright
©
2022 SOMFY ACTIVITES SA. All rights reserved.
2
4 4
3
4
MAINTENANCE
4.1
Checks
4.1.1 Safety devices
Check for correct operation every 6 months.
4.1.2 Backup battery
For optimum battery life, it is recommended that the main power supply be
switched off and the motor be operated using the battery for several cycles,
3 times a year.
4.2
Replacing the remote control battery
1
5
TECHNICAL DATA
GENERAL TECHNICAL DATA
Mains power supply
Max. power consumption
Climatic operating conditions
Radio frequency
Number of channels that can be
memorised
(One-way controls)
Programming interface
Remote lighting output
2
CR2430
or
CR 2032
220-230V - 50/60 Hz
800W (with 500W remote lighting)
- 20°C / + 60°C - IP 44
868 - 870 MHz, < 25mW
Total/partial opening control: 30
Lighting control: 4
Auxiliary output control: 4
7 buttons – 3-character LCD screen
230V - 500W (halogen or
incandescent only)
EN
15