1. EN – Instructions for use
1.1 Permissible use
The radiator may only be used for heating interior
spaces and for drying textiles washed in water.
Any other use is contrary to the intended purpose
and therefore not permissible.
Misuse
The radiator is not usable as a seating accom-
modation, climbing or lifting support.
1.2 Safety instructions
Warning
Risk of burns!
The radiator's surface can heat up to 110 °C
(230 °F).
Be careful when touching the radiator.
Caution
Risk of burns due to squirting hot water
when evacuating air!
Protect your hands.
1.3 Operating the heating fan
Observe separate instructions for the heating
fan.
1.4 Maintenance
Vent the radiator after commissioning and fol-
lowing lengthy interruptions of operation.
1.5 Cleaning
Use only mild, non-abrasive cleansing agents.
1.6 Complaint
Contact your local dealer.
1.7 Installation and repairs
Have the installation and repairs performed
by a specialized tradesman so that your claims
under warranty are not forfeited.
1.8 Disposal
Recycle or dispose of disused radiators, in-
cluding accessories, properly. Observe local
regulations
2. Installation
The radiator may only be installed by a speci-
alized tradesman.
Only a qualified electrician (in Germany acc. to
BGV A3) may connect the heating fan.
2.1 Safety instructions
Read these instructions for installation and use
thoroughly prior to installation/commissioning.
After installation, pass the instructions on to
the end user.
Pay attention to the safety information in the
separate instructions for electric components.
Danger
Life-threatening situation
Check the condition of the supply lines (elec-
tricity, gas, water).
Do not drill into any lines.
Warning
Risk of injury!
Note the radiator's weight (see page 6).
At 25 kg and above, work with lifting equip-
ment or several persons.
Warning
Personal injury and material damage!
Take the radiator's filled weight (see page 6) and
possible additional loads into consideration.
Check fasteners for applicability and tailor
them to the structural situation.
Special requirements, e.g. for public build-
ings (schools or the like), must be taken into
account.
2.2 Operating conditions
Observe operating conditions for water hea-
ting installations according to DIN 18380 "VOB
German Construction Contract Procedures".
Observe water's condition according to VDI
[Association of German Engineers] 2035
"Prevention of damage in water heating
installations".
Observe limitations of use in damp loca-
tions according to DIN 55900 "Coatings for
radiators".
Use radiator only in closed heating systems.
Store and transport radiator only in the protec-
tive packaging.
For operating the heating fan:
When installing in rooms with bath or
shower facilities: take into account pro-
tective areas according to national instal-
lation standards (in Germany DIN VDE
0100-701). Also follow all local regulations.
Note: The manufacturer does not approve the
installation of products in protective area 1.
Recommendation according to IEC stan-
dard 60335-2-43: To prevent any risk to
small children, install the radiator so that the
bottommost cross tubes are situated at least
600 mm above the floor.
2.3 Technical features
Operating pressure: max. 4 bar
Test pressure: 1.3 x operating pressure
Flow: available on the right or the left
Flow temperature:
– Hot water up to 110 °C (230 °F)
2.4 Directions for installation
Number of attachment points
Requirement class 2 according to VDI 6036 only
permissible if the recommended guideline values
for displacement and withdrawal forces in usual
connection situations are observed.
If necessary, mount additional bracket and lif-
tout / shift restraint device (refer to manufactu-
rer's documentation). Please also observe the
installation instructions of the dealer
The number of attachments points was deter-
mined and checked on vertically cored light-
weight brick T14.
Observe the dimension and position of the
connections.
Refer to the respective instructions or manu-
facturer's documentation for the number and
arrangement of separate fastening elements.
For operating the heating fan:
Observe separate instructions for the heating
fan.
Ensure that a correctly installed mounting box
or wall socket (230 V, 16 A fuse) is available
within the reach of the cable.
The electrical connection at the wall must be
freely accessible and must not project out to the
surface of the radiator. The radiator must not be
attached directly beneath a wall socket.
For installation in a one-pipe heater:
Use connection fitting with integrated, adjus-
table bypass.
2.5 Commissioning
Fill and vent the radiator.
Risk of scalding!!
Check radiator and connections for leaks.
3