NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
TROUBLESHOOTING INFORMATION:
If burner lights, but goes out when button is released.
CHECK
•
Loose wires on tipover switch.
•
Loose lead wire at control valve and ODS/Pilot
Assembly.
•
Loose thermocouple and tighten if necessary.
•
Defective ODS/Pilot Assembly. Replace if necessary.
•
Defective control. Replace if necessary.
•
Defective tip over switch. Replace if necessary.
Tip-Over Switch Arrangement
NOTE: The purpose of the Tip-Over Switch is to stop the flow of
gas when heater is accidentally knocked over. When and if the
heater is knocked over, simply stand heater up, wait 5 minutes
and relight.
ITEM
7
Portable Propane Cabinet Heater
REPLACEMENT PARTS LIST
PART
NO.
NUMBER
PANEL, FRONT, WHITE, HS18CH
1
27508
PANEL, TOP, WHITE, HS18CH
2
27509
27512
SHIELD, RADIATION, HS18CH
3
KNOB, CONTROL, HS18CH
4
27513
CASTER, LOCKING, HS18CH
5
27514
6
27515
ASSEMBLY, HOSE, REGULATOR
VALVE, CONTROL, HS18CH
7
27516
GUARD, WIRE, HS18CH
8
27517
27540
BRACKET, TANK, MOUNT,WHITE
9
SWITCH, TIPOVER, HS18CH
10
42116
SHIELD, HEAT, HS18CH
12
27524
BASE, METAL, HS18CH
13
27520
BASE, TANK, SUPPORT, HS18CH
14
27521
SCREW, HAND, BASE, HS18CH
15
27530
16
27531
BRACKET, HOUSING, SUPPORT
REFLECTOR, HS18CH
17
27529
GUARD, WIND, HS18CH
18
27528
BRACKET, ODS, HS18CH
19
27522
ODS, HS18CH
20
27523
ASSEMBLY, BURNER, HS18CH
21
27526
22
27941
O-RING, ORIFICE
ORIFICE, HS18CH
23
27527
24
27525
BRACKET, VALVE, MOUNT
HOLDER, ORIFICE, HS18CH
25
27532
Operating Instructions and Owner's Manual
DESCRIPTION