Télécharger Imprimer la page

Vivreau PURITY 450 Quell ST Mode D'emploi page 21

Publicité

Les langues disponibles

Les langues disponibles

10.4 Leak after Filter Replacement
Cause:
O-ring at the filter cartridge is not seated correctly.
Troubleshooting:
Check correct seat of the O-ring (Chapter 6.2).
!
and Safety Information (Chapter 3).
10.5 No Display Function
Cause:
Battery drained.
Troubleshooting:
Replace display unit (Order number see Chapter 13).
Note: When replacing the display unit, follow the enclosed manual.
10.6 Data on Display Flashing
Cause:
Monthly limit expired or the remaining capacity of the filter cartridge
is exhausted (Chapter 5.2).
Troubleshooting:
Replace filter cartridge (Chapter 6).
10.7 Bypass setting in the display does not agree with the setting
of the bypass screw (cf. 10.8/10.9)
Cause:
Filter was not commissioned correctly.
Troubleshooting:
Flush filter again (Chapter 5.4). Check data in the display after flushing
(Chapter 5.5).
10.8 Bypass setting in the display does not agree with the setting
of the bypass screw (cf. 10.7/10.8)
Cause:
Valve strip of the by-pass setting not set correctly.
Troubleshooting:
Flush filter system again and readjust bypass screw (Chapter 5.3)
11 Battery
The installed battery is designed for a service life of approx. 10 years.
The battery and display unit must not be burnt and must not be disposed of in domestic waste;
please hand in the battery and the appliance to the collecting points designed for this purpose in line
with the local regulations.
To remove the battery, please proceed as follows:
Remove the screw on the back of the display unit and open and remove the back of the housing.
Disconnect the soldered contacts on the battery with side cutters and remove the battery from
the bracket.
Replace back of the housing on the display unit and tighten screw.
Dispose of the battery and display unit following
the local environmental guidelines for battery disposal
12 Technical Data
Operating pressure
Operating/water temperature
Ambient
operation
temperature
storage/transport
during
Flow rate with 1 bar (14.5 psi)
pressure loss
Empty filter cartridge volume
Weight (dry/wet)
Dimensions complete system
(Width/Depth/Height)
Caution: Prior to dismantling read the data (Chapter 12) and the Operating
Filter system VIVREAU PURITY with filter cartridge
PURITY 450 Quell ST*
300 l/h (79.2 US gallons/h)
3,9 l (1.03 gallon)
10 kg/12 kg (22 lb/26 lb)
249 mm (9.80 inch)
222 mm (8.74 inch)
408 mm (16.06 inch)
.
PURITY 600 Quell ST
2 bar – max. 6,9 bar (29 psi – max. 100 psi)
4°C – 30°C (39°F – 86°F)
10°C – 40°C (50°F – 104°F)
–20°C – 50°C (–4°F – 122°F)
300 l/h (79.2 US gallons/h)
5,8 l (1.5 gallon)
12 kg/15 kg (26 lb/33 lb)
249 mm (9.80 inch)
222 mm (8.74 inch)
520 mm (20.47 inch)
PURITY 1200 Quell ST
300 l/h (79.2 US gallons/h)
10,9 l (2.8 gallon)
18 kg/24 kg (40 lb/53 lb)
288 mm (11.34 inch)
255 mm (10.04 inch)
550 mm (21.65 inch)
17