Parameter input water hardness and filter system size
At this level, parameters needed for operation are set manually.
The type and size of filter system is selected, the unit of hardness is set, the local carbonate hardness
or total hardness of the tap water is entered, and the maximum cartridge service life (monthly limit)
is activated. After this the parameters must be accepted.
•
To activate the display, press the back button once
(< 1 second) until the data field appears.
•
Press and hold the button (> 4 seconds and
< 10 seconds) until the parameter input for the filter
system type and size flashes.
•
Press and hold the button (> 2 seconds) until the filter
system type (STD, STM, FIN) and corresponding value
for the filter system size (04, 06, 12) has been reached.
•
Press the button once (< 1 second) to access the next
parameter input unit of hardness. The unit of hardness
flashes.
EN
•
Press and hold the button (> 2 seconds) until the desired
unit of hardness has been selected.
•
Press the button once (< 1 second) to access the next
parameter input hardness value. The hardness value
input flashes.
•
Press and hold the button (> 2 seconds) until the value
for the water hardness rises and keep it pressed until
the desired value has been reached.
•
Press the button (< 1 second) to access the next
parameter input monthly limit. The monthly limit input
flashes.
8
< 1 sec
> 4 sec
> 2 sec
< 1 sec
> 2 sec
< 1 sec
> 2 sec
< 1 sec
FIN