Operating instructions
Access and errors codes for the AQUAPRO LOGIC CONTROL module
1. « Lbat »: indicates the input voltage is too low at below 11 Vdc.
2. « ½ second off flashing screen and ½ second normal screen » indicates it is now the time to do the pump maintenance, (oil
change and general verifi cation).
a. When the pump maintenance is done, push and hold 5 seconds the Pump button to start a new 200 hours chrono for the pump
maintenance.
3. If the burner is not in function, « xxx » indicates the hours cumulated since the last pump maintenance.
4. If the burner is in function, « xxx » indicates the temperature in Fahrenheit* degree.
a. During the fi rst 5 seconds, « xxx » indicates the setting temperature.
b. Then « xxx » indicates the actual sensor temperature located at the coil outlet.
c. Then « deS » indicates the "weed control temperature" is reached.
5- « ---- » indicates the temperature sensor is faulty.
6- *: to indicate the temperature in Celsius degree, push and hold 2 seconds the 2 temperature arrow buttons.