ENGLISH
9. Repairs
A
Danger!
Repairs to electric tools must
only be carried out by a qualified
electrician!
Electric tools in need of repair can be
sent to an authorised service center in
your country. See spare parts list for
address.
Please attach a description of the fault to
the electric tool.
12. Technical Specifications
Mains voltage
Frequency
Rated output
Rated current
Fuse protection min. (time-lag or L-type circuit breaker)
Running capacitor
Rated speed
Pump capacity max.
Delivery head max.
Delivery pressure max.
Immersion depth max.
Standing water max.
Temperature of the primed medium max.
Degree of protection
Protection class
Insulation class
Materials
Pump casing
Pump shaft
Impeller
Power cable (HO 7 RN-F)
Discharge port (AG=male, IG=female)
Dimensions (pump casing)
Height
Width
Diameter
Weight
Max. length of extension cable
2
at 3 x 1.0 mm
lead cross-section
2
at 3 x 1,5 mm
lead cross-section
10
10. Environmental Protection
The packaging of the pump can be
100 % recycled.
Worn out power tools and accessories
contain considerable amounts of valua-
ble raw and plastic materials, which can
be recycled.
These instructions are printed on chlo-
rine-free bleached paper.
11. Available Accessories
For this equipment the following acces-
sories are available at specialist dealers.
3
Note:
Illustrations and stock numbers
can be found at the end of these instruc-
tions.
A
Elbow
Inlet port thread:
1 1/4" male
Dicharge port thread:
1" female + 1 1/4" male
V
230
Hz
50
W
750
A
3,3
A
10
F
8
-1
min
2800
l/h
19000
m
9
bar
0,9
m
5
mm
30
°C
35
IP 68
I
B
Polypropylene
Stainless steel
Noryl
m
10
1 1/4" female
mm
300
mm
150
mm
140
kg
6,0
m
30
m
50
1