8.1

Fault finding

Pump does not run:
No mains voltage.
 Check cables, plug, outlet and
mains fuse.
Mains voltage too low.
 Use only extension cables with
sufficient lead cross section (see

"Technical Specifications").

Motor overheated, motor protection
relay tripped.
 Remove cause for overheating
(fluid pumped too hot? Pump
blocked by foreign objects?)
 After cooling off the pump will
switch ON again.
Float switch does not switch the
pump ON.
 Ensure a sufficient supply of
water.
 Make sure the float switch can
move unrestricted.
11. Technical Specifications
Mains voltage
Frequency
Rated output
Rated current
Fuse protection min. (time-lag or L-type circuit breaker)
Running capacitor
Rated speed
Pump capacity max.
Delivery head max.
Delivery pressure max.
Immersion depth max.
Standing water max.
Max. temperature of primed medium
Protection class
Degree of protection
Insulation class
Materials
Pump casing
Pump shaft
Impeller
Power cable (HO 5 RN-F)
Discharge port thread (AG = male)
Dimensions (pump casing)
Height
Width
Diameter
Weight
Max. length of extension cable
2
at 3 x 1.0 mm
2
at 3 x 1.5 mm
Motor hums but does not start:
Pump blocked by foreign object.
 Clean pump.
Pump does not pump properly:
Delivery head too high.
 Observe max. delivery head (see
Discharge hose kinked.
 Straighten discharge hose.
Discharge hose leaky.
 Seal discharge hose, tighten
Pump runs very noisily:
Pump primes air.
 Ensure a sufficient supply of
 Adjust float switch correctly.
 Hold pump at an angle when sub-
Pump runs continuously:
Float switch does not reach cut-out
position.
 Make sure the float switch can
 Set to Manual mode, unplug.
lead cross-section
lead cross-section
"Technical Specifications").
screw fittings.
water.
merging.
move unrestricted.
V
Hz
W
A
A
F
min
l/h
m
bar
m
mm
°C
m
mm
mm
mm
kg
m
m

9. Repairs

A
Danger!
Have your power tool serviced by a
qualified repair person using only
identical replacement parts. This will
ensure that the safety of the power
tool is maintained.
Contact your local Metabo representa-
tive if you have Metabo power tools
requiring repairs. See www.metabo.com
for addresses.
You can download a list of spare parts
from www.metabo.com.

10. Environmental Protection

The packaging of the pump can be
100 % recycled.
Worn out power tools and accessories
contain considerable amounts of valua-
ble raw and plastic materials, which can
be recycled.
These instructions are printed on paper
produced with elemental chlorine free
bleaching process.
TP 7500Si
230  1
50
300
1.4
10
8
-1
2800
7500
6.5
0.65
7
3
35
IP 68
I
B
Polypropylene
Stainless steel
Noryl
10
1 1/4" AG
285
185
227
4.2
60
100
ENGLISH
TP 12000Si
600
2.5
10
10
2800
11700
9
0.9
7
3
35
IP 68
I
B
Polypropylene
Stainless steel
Noryl
10
1 1/4" AG
320
190
230
5.1
60
100
13

Publicité

loading

Ce manuel est également adapté pour:

Tp 12000 si