2. Installation
2.1 General Instructions
BOILER INSTALLATION MUST ONLY BE PERFORMED BY QUALIFIED PERSONNEL, IN ACCORDANCE WITH
ALL THE INSTRUCTIONS GIVEN IN THIS TECHNICAL MANUAL, THE PROVISIONS OF CURRENT LAW, THE PRE-
SCRIPTIONS OF NATIONAL AND LOCAL STANDARDS AND THE RULES OF PROPER WORKMANSHIP.
2.2 Place of installation
The combustion circuit is sealed with respect to the place of installation and therefore the unit can be installed in any
room. However, the place of installation must be sufficiently ventilated to prevent the creation of dangerous conditions
in case of even small gas leaks. This safety measure is required by EEC Directive no. 90/396 for all gas units, including
so-called sealed chamber types.
The unit is suitable for operation in a partially protected place in conformity with EN 297 pr A6, with minimum tempera-
ture -5°C. If equipped with the special antifreeze kit it can be used with minimum temperature as low as -15°C. It is ad-
visable to install the boiler under the slope of a roof, inside a balcony or in a sheltered recess.
Therefore the place of installation must be free of dust, flammable materials or objects, and corrosive gases.
The boiler is arranged for wall mounting; by request a metal template is available for marking the drilling points on the
wall. The wall fixing must ensure a stable and effective support for the generator.
If the unit is enclosed in a cabinet or mounted alongside, a space must be provided for removing the casing
A
and for normal maintenance operations.
2.3 Plumbing connections
The heating capacity of the unit must be previously established by calculating the building's heat requirement according
to current regulations. The system must be provided with all the components for correct and regular operation. It is ad-
visable to install on-off valves between the boiler and heating system allowing the boiler to be isolated from the system
if necessary.
B
The safety valve discharge must be connected to a funnel or collection pipe, to prevent water spurting onto
the floor in case of overpressure in the heating circuit. Otherwise, if the discharge valve cuts in and floods the
room, the boiler manufacturer cannot be held liable.
Do not use the water system pipes to earth electrical appliances.
Before installation, carefully wash all the pipes of the system to remove any residuals or impurities that could affect prop-
er operation of the unit.
Carry out the relevant connections according to the diagram in sec. 4.1 and the symbols given on the unit.
The connection kits shown in the figure below (fig. 18) are supplied standard
A - Female sleeve
B - OT 58 nipple
C - O-ring
D - OT 58 clamping ring
E - Copper washer
F - OT 58 fitting
G - Ball cock
42
fig. 18 - Connection kits
cod. 3540F611 - 05/2007 (Rev. 00)
NINFA 24 MCS
A
B
C
D
E
F
C D E
F
A
G