7.
TECHNICAL DETAILS
Input data
Measuring ranges
Overload range
Burst pressure
Parts in contact with media
Output data
Curve deviation at max. setting to
DIN 16086 (accuracy class)
Curve deviation at min. setting
Temperature
compensation zero point
Temperature
compensation over range
Linearity at
max setting to DIN 16068
Hysteresis
Repeatability
Rise time
Long-term drift (6 months)
Ambient conditions
Nominal temperature range
Operating temperature range
Storage temperature range
Fluid temperature range
mark
Vibration resistance to
IEC 68-2-6 at 10 ..500 Hz
Safety type to DIN 40050
Other data
Supply voltage 2–conductor
Supply voltage 3–conductor
Residual ripple supply voltage
Reverse polarity protection of
the supply voltage, excess voltage,
override and short circuit protection
Current consumption 3-conductor
Life expectancy
Weight
Note:
( ull cale) = relative to the complete measuring range
Special models available on request.
HDA 3400
16; 60; 100; 250; 400; 600 bar
150 % FS
300 % FS
stainless steel, Viton seal
1 % FS
0.6 % FS
Max.
0.25 % / 10K
Typ.
0.15 % / 10K
Max.
0.25 % / 10K
Typ.
0.15 % / 10K
Max.
0.3 % FS
Typ.
0.2 % FS
Max.
0.4 % FS
Typ.
0.25 % FS
0.1 % FS
1 ms
Max.
0.3 % FS
0...+70 °C
-25...+85 °C
-40...+100 °C
-40...+100 °C
EN 50081-1, EN 50081-2,
EN 50082-1, EN 50082-2
approx. 20 g
(196.2 m/s²)
IP 65
10 .. 30 V
12 .. 30 V
5 %
available
approx. 15 mA
³
10 Mio. load cycles
approx. 180 g
8