Always be attentive when operating the
 
product .
Do not leave hanging loads unattended
 
without taking appropriate safety measures .
Do not stand or work underneath raised
 
loads .
The product has not been outfitted with a
 
rated power limit . Do not attempt to lift the
load further when the overheat protection
limits operation . In this case, the load has
exceeded the product's nominal power .
Do not use the maximum/minimum length
 
levers
routinely as a stop mechanism .
15 ]
[
[
16 ]
These levers serve as a stop mechanism only
in emergencies .
Before you begin: Check whether
 
the steel cable
[
14 ]
around the drum
the space between coils is less than the
diameter of the cable itself (Fig . D) .
˜ Before first use
Remove the packaging materials .
 
Remove the transport lock from the steel
 
cable
. Cut the rubber band and remove it .
[
14 ]
Before you begin: Check whether
 
the steel cable
14 ]
[
around the drum
the space between coils is less than the
diameter of the cable itself (Fig . D) .
Make sure the steel cable
 
maximum/minimum length levers
properly and without touching them (Fig . B) .
is wound properly
and whether
17 ]
[
is wound properly
and whether
17 ]
[
passes the
14 ]
[
15 ]
[
16 ]
[
˜ Assembly
(Fig . E)
m
DANGER!
The square tube (cross sectional
u
dimensions: 45 x 45 mm) must be able
to bear a minimum load of 500 kg at
the points where the product is fastened .
It is recommended to consult qualified
personnel (for example a structural
engineer) for assembly .
Because special knowledge is required,
u
seek advice from a qualified technician to
ensure all screws are tightened fully and
correctly .
A qualified technician or a properly trained
u
person should also check the anchoring
of the square tube before the product is
fastened .
Time needed for assembly: approx . 1 hour
u
Fasten the product with the mounting
 
brackets
and the mounting screws
1 ]
[
suitable square tube .
Tighten the mounting screws
 
˜ Operation
NOTE
The product has been outfitted with a
u
thermostat switch . During operation, it may
stop the motor
3 ]
[
started again once it has cooled down .
˜ Winding/unwinding the cable
(Fig . J)
Winding the cable: Press the control
 
switch
upwards according to the arrow
8 ]
[
indication .
Unwinding the cable: Press the control switch
 
downwards according to the arrow
8 ]
[
indication .
to a
[
2 ]
.
2 ]
[
. The motor can be only
GB/IE