TECHNICAL DATA
Cutting area
Max tilt
Cutting height
Cutting width
Battery
Battery capacity
Run time
Charging time
Voltage
Mulcher function
Dimensions
Weight
Sound pressure level, LpA
Sound power level, LwA
Guaranteed sound power level
Always wear ear protection!
The declared values for vibration and noise,
which have been measured according to a
standardised test method, can be used to
compare different tools with each other and for
a preliminary assessment of exposure. Noise
emission has been measured and declared in
accordance with EN 506362107:2015
WARNING!
The actual vibration and noise level when
using tools may differ from the specified
maximum value, depending on how the
tool is used and the material. It is therefore
necessary to determine which safety
precautions are required to protect the user,
based on an estimate of exposure in actual
operating conditions (taking into account all
stages of the work cycle, e.g. the time when
the tool is switched off and when it is idling,
in addition to the start-up time).
300 m²
27%
20–50mm
160mm
LiIon
2 Ah
70 min
3,3 h
20 V
Yes
49.8 x 32 x 20.3 cm
5.5 kg
50 dB(A), K= 3 dB
58 dB(A), K= 2.52 dB
61 dB(A)
DESCRIPTION
Silent robot lawn mower with a digital display
screen and rain sensor. Charging station,
perimeter wire, wire pegs and nine blades are
included.
INSTALLATION
INSTALLATION OF CHARGING
STATION
IMPORTANT:
•
The charging station must be positioned
on level, horizontal ground. It must not
be installed on a slope. The surface must
be flat so that the base plate is not
buckled or creased.
•
The charging station can be placed next to
a shed or house wall. Position the
charging station where there is at least
1 m of straight perimeter wire with no
obstacles in front of the charging station.
NOTE:
Make sure that there are no corners or
creases in the wire.
•
The mains adapter should be mounted on
a wall, at least 30 cm off the ground. The
low voltage cable should be laid outside
the mowing area, if possible. If it is
necessary to lay the cable partly or
completely inside the mowing area, the
cable must be buried.
FIG. 1
1.
Strip approx. 10 mm of insulation off one
end of the perimeter wire.
FIG. 2
2.
Connect the perimeter wire to one of
the terminals. The red terminal (A) is the
system's OUT direction. Pull the connected
perimeter wire through the opening
in the charging station base plate. Lay
out the perimeter wire and peg it to the
ground along the edge of the mowing
area. When the perimeter wire has been
laid completely and you are back at the
base station, cut off the excess wire, strip
EN