Operation with RAPTOR series control panels
The RAPTOR control panel allows you to acquire maximum of 4 repeaters which must be previously addressed via DIP1 and DIP2
and acquired.
DIP 1 DIP 2
REPEATER NUMBER
OFF
OFF
REPEATER N° 1
ON
OFF
REPEATER N° 2
OFF
ON
REPEATER N° 3
ON
ON
REPEATER N° 4
1. Before acquisition, carry out a Reset of the wireless Codes by setting DIP switches 5, 6, 7 and 8 to ON:
DIP 5 DIP 6 DIP 7 DIP 8
ON
ON
ON
ON
2. The repeater LED turns on WHITE to confirm the reset; then return DIP switches 5, 6, 7 and 8 to OFF.
3. To acquire the repeater in the control panel, once you have entered the "Radio Dev.ManagRPT WS4ModifyAcquisition"
menu, transmit the tamper of the repeater. Check that the control panel confirms the acquisition via the message on display and
the buzzer sound.
4. After acquiring the wireless devices in the control panel, it is necessary to indicate which detectors and/or sirens must also be
managed by the repeater (all remote controls are repeated in any case). To do this you need to enter the programming menu of
each device to be repeated and in the "Repeater menu"; select: RPT WS4 n°, where n (1...4) indicates the number of the repeater
that must be repeated by that wireless device.
Example: to associate the Wireless detector n° 5 to the Repeater 1 it is necessary to program in the control panel "Radio Dev.
ManagSensorsModifyDetector ProgramDetector 5Repeater WS4RPT WS4" and set "1".
5. To make the association effective, it is necessary to exit the control panel programming menu and cause a transmission of the
repeater or wait maximum 15 minutes.
6. It is possible to test the repeater directly from the control panel by entering the "Radio Dev. ManagRPT WS4VerifyTest"
and pressing the number (1..4) corresponding to the repeater to be tested; you can see the wireless signal level and power sup-
ply. It is possible that the wireless signal alternately indicates two different levels; this is due to the presence of two antennas on
the repeater.
Operation with compatible AVS control panels (NO Raptor)
In the AVS control panels, which do not integrate the wireless repeater management menu, it is still possible to configure and use
one or more repeaters according to requirements using a different repeater for each wireless satellite connected to the control panel.
• Tampering, survival and technical failure information is not managed by the control panel.
DIP 5 DIP 6 DIP 7 DIP 8
OFF
OFF
OFF
OFF
1. Before acquisition, carry out a Reset of the wireless Codes by setting DIP switches 5, 6, 7 and 8 to ON:
DIP 5 DIP 6 DIP 7 DIP 8
ON
ON
ON
ON
the repeater LED turns on WHITE to confirm the reset; then return DIP switches 5, 6, 7 and 8 to OFF.
2. After having acquired the detectors in the wireless Satellite, the wireless detectors can also be acquired in the Repeater. Move
dip switches 5 and 8 to ON. The LED flashes white once a second.
DIP 5 DIP 6 DIP 7 DIP 8
ON
OFF
OFF
ON
3. Transmit the tamper of one of the detectors to be repeated; in the repeater the LED turns yellow for about one second and then
returns to flashing white. At this point the repeater is also ready to repeat the wireless siren if present.
• Remote controls are always repeated anyway.
4. Transmit the tamper of any other detectors to be repeated checking that each time the repeater LED turns yellow for about one second.
5. Move all the repeater Dip-Switches back to OFF to stop the procedure.
• If you need to add other detectors acquired in the paired Wireless Satellite to the RPT WS4, repeat steps from 2 onwards.
• If there are sirens and wireless detectors to be repeated associated with other wireless satellites in the system, it is necessary
to install as many repeaters as the satellites with devices to be repeated. Carry out the procedure described on each one with
the detectors that must be repeated.
DIP 5 DIP 6 DIP 7 DIP 8
OFF
OFF
Reset of the wireless Codes (White Led on permanent mode).
Normal operation (Red led during repeat).
Reset of the wireless Codes (White Led on permanent mode).
Acquisition of detectors to be repeated (flashing white LED or yellow LED in detector acquisition).
OFF
OFF Normal operation (Red led during repeat)