General features
Managed Detectors
Managed Sirens
Managed Remote control
Wireless range
Programming
Board dimension
Power
Battery
Current absorbed by the 230 VAC
Autonomy only battery
230 VAC Input fuse
Container dimensions (LxHxP)
Environmental conditions
Protection rating
Environmental class
Occupied frequency bands
(ETSI EN 300 220-3-2 V1.1.1 (2017-02)
Wireless alarm equipment)
868,600 MHz to 868,700 MHz
A
D
869,300 MHz to 869,400 MHz
869,650 MHz to 869,700 MHz
E
Occupied frequency band for image trasmission
(ETSI EN 300 220-3-2 V3.1.1 (2017-02)
Non-specific short range devices)
868,700 MHz to 869,200 MHz
The RPT WS 4 is supplied fully wired:
• Mains Power Input 230 VAC_____________
• Tamper______________________________
• Led (underside)_______________________
• Dip_Switch___________________________
• Terminal block (look at TERMINAL BLOCK Table)_
• Power supply_________________________
• Faston battery 12 V - 1,2 Ah connection____
TERMINAL BLOCK
-
Tamper Input (NC Contact)
T
Tamper Input (NC Contact)
-
12 V = Negative Input Power Supply
DB
Negative Connection Output for Battery
DA
Positive Connection Output for Battery
+
12 V = Positive Input Power Supply
The repeater must be installed at least 20 cm away from metal containers or electrical appliances that could disturb its
functioning.
INSTALLATION AND MAINTENANCE (E.G. REPLACING THE BATTERY, FUSES, ETC.) MUST BE EXECUTED BY QUALIFIED PERSONNEL
The product complies with the European Directives for the CE marking.
INSTALLATION MANUAL
According to the control panel installed
Raptor: n° 2
No limits
700 mt in open field
on the module using DIPs
119 x 83 x 10 mm.
Input 110/250 VAC - 0,5 A - 50/60 Hz
max: 12V = 1.2Ah
20 mA without battery recharge
more than 48 hours with a fully charged battery
500 mA delayed
225 x 210 x 73 mm.
+5 °C / +55 °C
IP30
Class II
Maximum
According to EC Decision
radiated power
2013/752/EU [i.2]
<10 mW e.r.p.
<10 mW e.r.p.
<10 mW e.r.p.
Maximum
According to EC Decision
radiated power
2013/752/EU [i.3]
<10 mW e.r.p.
- 6 -
Other control panels: n°1
Output 15 V= - 1A
100 mA with battery recharge
Band number
Class 1 sub-class number
Commision Decision 2000/299/EU [i.5]
49
53
55
Band number
Class 1 sub-class number
Commision Decision 2000/299/EU [i.7]
50
32
72
34
29