The same tilt angle must be set on both sides.
Adjusting the scarifi er depth (see Fig. 16)
The scarifi er depth is set with the adjustment me-
chanism. Pull the lever in the direction indicated
by the arrow (see Fig. 16) and adjust to the requi-
red position (+3/-3/-6/-9). Make sure that the lever
latches in place correctly!
+3 = drive/transport position +3 mm
-3 = scarifi er depth -3 mm
-6 = scarifi er depth -6 mm
-9 = scarifi er depth -9 mm
Charging the battery (Fig. 17/19)
The equipment is supplied without batteries and
without a charger!
1. Take the battery pack out of the equipment.
Do this by pressing the pushlock buttons.
2. Check that your mains voltage is the same as
that marked on the rating plate of the battery
charger. Insert the power plug of the charger
(19) into the socket outlet. The green LED will
then begin to fl ash.
3. Insert the battery pack (18) into the battery
charger (19).
4. In the section entitled „Charger indicator" you
will fi nd a table with an explanation of the LED
indicator on the charger.
The battery pack can become a little warm during
the charging. This is normal.
If the battery pack fails to charge, check:
•
whether there is voltage at the socket outlet
•
whether there is good contact at the charging
contacts
If the battery pack still fails to charge, send
•
the charging unit
•
and the battery pack
to our customer service center.
To ensure that items are properly packaged
and delivered when you send them to us,
please contact our customer service or the
point of sale at which the equipment was
purchased.
When shipping or disposing of batteries and
cordless tools, always ensure that they are
packed individually in plastic bags to prevent
short circuits and fi res.
Anl_GE_SA_36_35_Li_SPK13.indb 24
Anl_GE_SA_36_35_Li_SPK13.indb 24
GB
To ensure that the battery pack provides long ser-
vice, you should take care to recharge it promptly.
You must recharge the battery pack when you
notice that the performance of the device drops.
Never allow the battery pack to become fully di-
scharged. This will cause it to develop a defect.
Installing the battery (Fig. 18-19)
Open the battery cover (Fig. 18 / Item 7). Then
push the two batteries into the mounts as shown
in Fig. 19 until you hear the batteries engage.
Note!
Use only batteries which are charged to the same
level. Never combine full and half-full batteries.
Always charge the two batteries simultaneously.
The equipment's operating time depends on the
battery with the lower charge level. The two bat-
teries must always be fully charged before use.
Close the battery cover by swinging it down, and
make sure that it latches in place correctly.
Battery capacity indicator (Fig. 20)
Press the switch for the battery capacity indicator
(Fig. 20/Item A). The battery capacity indicator
(Fig. 20/Item B) shows the charge status of the
battery using 3 LEDs.
All 3 LEDs are lit:
The battery is fully charged.
2 or 1 LED(s) are lit:
The battery has an adequate remaining charge.
1 LED fl ashes:
The battery is empty, recharge the battery.
All LEDs blink:
The battery temperature is too low. Remove the
battery from the equipment, keep it at room tem-
perature for one day. If the fault reoccurs, this me-
ans that the rechargeable battery has undergone
exhaustive discharge and is defective. Remove
the battery from the equipment. Never use or
charge a defective battery.