The remote
There is too much distance
control does
between the machine and
not work.
the remote control.
The remote control is not
aligned with the direction
of the remote control
receiver.
The remote
Batteries are dead.
control does
not work.
Displays 'E1'.
The room temperature
sensor is abnormal.
The display
The pipe temperature
shows "E2".
sensor is abnormal.
1. Service information
1.1. Area verification
Before starting work on systems containing flammable refrigerants, safety checks are
necessary to ensure that the risk of ignition is minimised. Before repairing the cooling system,
the following precautions must be observed:
1.2. Work procedure
The work must be carried out in accordance with a controlled procedure to minimise the risk of
a flammable vapour or gas being present while the work is being carried out.
1.3. General workspace
All maintenance personnel and others working in the area should be briefed on the nature
of the work to be carried out. Work in confined spaces must be avoided. The area around the
workspace should be divided into sections. Ensure that conditions within the workspace are
safe by keeping flammable material under control.
1.4. Refrigerant verification
The area should be checked with an appropriate refrigerant detector before and during
work to ensure that the technician is warned of potentially flammable atmospheres. Ensure
that the leak-detection equipment used is suitable for use with flammable refrigerants, i.e.,
non-sparking, adequately sealed, or intrinsically safe.
1.5. Presence of fire extinguishers
Let the remote control get close to the
air conditioning, and make sure that
the remote control directly faces to the
direction of the remote control receiver.
Replace batteries.
Contact the official Technical Support
Service of Cecotec.
Contact the official Technical Support
Service of Cecotec.