ADJUSTING THE TEMPERATURE CURVE
The user can define a temperature curve to adjust the set point automati-
cally over a given time period.
Temperature
T
1
o
T
2
o
T
3
o
T
4
o
T
5
o
T
6
o
A curve is defined using six points. Each point specifies a day number and
a set point for that day. Once the points of the curve are defined, the curve
must be activated. The controller will change the temperature set point
every hour in a linear fashion between consecutive points of the curve.
When the last point of the curve is reached, the temperature set point for that
day is maintained until the curve is reactivated.
The temperature set point and the points
of the temperature curve can only be
adjusted if the temperature curve is de-
activated. If the pilot light is turned on,
the temperature curve is currently acti-
vated.
Deactivating the temperature curve:
Set the parameter selection knob to SET POINT / T° CURVE.
The current set point is displayed.
Press the push-button repeatedly until the word ON appears
flashing on the display.