TEMPERATURE SETTINGS
VIEWING TEMPERATURES
To view the room temperature and the
temperature measured by each probe:
Set the parameter selection knob
to ROOM TEMPERATURE. The
room temperature appears on the
display.
The room temperature shown on the
display is the average value of all
temperatures measured by probes that
are activated and in proper operating
condition.
Press the push-button. The letters "PR1" and the temperature
measured by the probe connected to terminal # 1 alternate on the
display.
For each additional probe connected to the controller:
Press the push-button once again. The letters "PR#" (# is
thenumber of the terminal to which the probe is connected) and
the temperature measured by the probe alternate on the display.
ADJUSTING THE SINGLE SET POINT
The controller maintains a specified tar-
get room temperature by controlling the op-
eration of the fans and heating units. The tar-
get room temperature can be specified in two
ways: a single set point or a temperature
curve. When using a single set point, the
controller operates according to the
specified temperature as long as the tem-
perature curve is deactivated.
TC4-NVS/P.rev.05