TC4-NVS/P
To identify the faulty probe:
Set the selection knob to ROOM
TEMPERATURE. The room tem-
perature is displayed.
Press the push-button. If the
probe connected to terminal # 1 is
not faulty, "Pr 1" is displayed, alter-
nating with the temperature mea-
sured by the probe. Otherwise, "Pr
1" alternates with "P".
Press the push-button once again to display the status of probe 2.
STEP 4 - STAGE 2 OPERATION
Stage 2 can be configured for heating, ventilation, mist or recirculation.
Use internal switches # 4, 5 and 6 to configure the stage.
V
E
N
T
L I
A
I T
H
E
A
I T
N
G
M
I
T S
R
E
C
R I
C
U
L
FACTORY SETTING: When the controller is shipped from the factory,
Stage 2 is configured for ventilation.
12
TC4-NVS/P.rev.05