TC4-NVS/P
The temperature set point and the points
of the temperature curve can be ad-
justed only if the temperature curve is
deactivated. If the pilot light is turned
on, the temperature curve is currently
activated.
Deactivating the Temperature Curve:
Set the parameter selection knob to SET POINT / T° CURVE.
The current set point is displayed.
Press the push-button repeatedly until the word ON appears
flashing on the display.
Turn the adjustment knob counterclockwise one notch and leave
it in this position. The word OFF appears flashing on the display
and after 10 seconds, the temperature curve pilot light turns off
indicating that the temperature curve is now deactivated.
Adjusting the single set point:
Set the parameter selection knob to SET POINT / T° CURVE.
The current set point is displayed.
Turn the adjustment knob to adjust the set point to the desired
value.
18
TC4-NVS/P.rev.05