Troubleshooting
Before calling for service, review this list. It may save your time and expense. This list includes common occurrences that are not the result
of defective workmanship or materials in this appliance.
Problem
Air conditioner does not start
Air from unit does not feel cold enough
Air conditioner cooling, but room is too warm – ice forming on
cooling coil behind decorative front.
Air conditioner cooling, but room is too warm – NO ice forming
on cooling coil behind decorative front.
Air conditioner turns on and off rapidly
□
Wall plug disconnected. Push plug rmly into wall outlet.
□ House fuse blown or circuit breaker tripped. Replace fuse with
time delay type or reset circuit breaker.
□ Plug current device tripped. Press the RESET button.
□ Power is OFF. Turn power ON.
□ Room temperature below 62°F (17°C). Cooling may not occur until
room temperature rises above 62°F (17°C).
□ Temperature sensing behind air lter element touching cold coil.
Keep it from the cold coil.
□ Set to a lower temperature.
□ Compressor stopped when changing modes. Wait for 3 minutes
after set to the COOL mode.
□ Outdoor temperature below 64°F (18°C). To defrost the coil, set to
FAN ONLY mode.
□ Air lter may be dirty. Clean lter. Refer to Care and Cleaning
section. To defrost, set to FAN ONLY mode.
□ Thermostat set too cold for nighttime cooling. To defrost the coil,
set to FAN ONLY mode. Then, set temperature to a higher setting.
□ Dirty air lter- air restricted. Clean air lter. Refer to Care and
Cleaning section.
□ Temperature is set too high, set temperature to a lower setting.
□ Front of unit is blocked by drapes, blinds, furniture, etc. - restricts
air distribution. Clear blockage in front of unit.
□ Doors, windows, registers, etc. open- cold air escapes. Close doors,
windows, registers.
□ Unit recently turned on in hot room. Allow additional time to
remove stored heat from walls, ceiling, oor and furniture.
□
Dirty air lter- air restricted. Clean air lter.
□ Outside temperature extremely hot. Set FAN speed to a higher
setting to bring air past cooling coils more frequently.
19
Please contact 1-877-527-0313 for further assistance.
Solution
HOMEDEPOT.COM